
7. SETTING UP THE INSTRUMENT
32
3. Press
{ON}
to power on
• The circular level is displayed on
the screen.
• “
” indicates bubble in circular
level. The range of the inside
circle is ±4' and the range of the
outside circle is ±6'.
Tilt angle values X and Y are also
displayed on the screen.
• “
” is not displayed when the tilt
of the instrument exceeds the
detection range of the tilt sensor.
Level the instrument while
checking the air bubbles in the
circular level until “
” is
displayed on the screen.
• When executing the measurement
program, if measurement starts with
the instrument tilted, the circular level
is displayed on the screen.
4. Center “
” in the circular level
steps 1 to 2
• If the bubble is centered, move to
step 9.
5. Turn the instrument until the
telescope is parallel to a line
between levelling foot screws A
and B, then tighten the horizontal
clamp.
OK
OK