16. SETTING-OUT LINE
12. Press
[OK]
on the screen of step
11 to define the baseline. <Set-out
line> is displayed. Move to setting-
line measurement.
"16.2 Setting-out Line Point"/
• Press
[Sy=1]
to set scale factor
y to “1”.
• Press
[1 : **]
to change the
grade display mode to “1 : * * =
elevation : horizontal distance”.
• It is also possible to perform setting-out line measurement by pressing
[S-O
LINE]
when allocated to the OBS mode screen.
Allocating
[S-O LINE]
: "33.3 Allocating Key Functions".
PROCEDURE Defining by observation
1. In the second page of OBS mode
screen, press
[MENU]
, then select
"S-O line".
2. Enter the instrument station data.
Station Data and Azimuth
Angle"
3. Select “Define baseline” in <Set-
out line>.
4. Sight the first point and press
[MEAS]
.
• Press
[STOP]
to stop the
measurement.
• The tilt screen is displayed if the
instrument is out of level.
Level the instrument.
S e t - o u t l i n e
P o i n t
L i n e
D e f i n e 1 s t P T
N p :
E p :
Z p :
0 . 0 0 0
0 . 0 0 0
0 . 0 0 0
REC
LOAD
MEAS
OK