Handbuch / Manual

2

Summary of Contents for SH ARC-PCMCIA

Page 1: ......

Page 2: ...Handbuch Manual 2 ...

Page 3: ...eben werden LED Anzeigen an dem Netzwerk Schnittstellen Modul 8 3 7 LED Anzeigen an dem Netzwerk Schnittstellen Modul 9 4 ARCNET Schnittstellen 9 4 1 Koaxiale Schnittstelle SH KOAX PCMCIA 9 4 2 RS 485 EIA 485 Schnittstelle SH RS485 PCMCIA 9 4 3 RS485AC Schnittstelle SH RS485AC M 11 4 4 Twisted Pair Schnittstelle SH TWP PCMCIA 11 4 5 LWL Schnittstellen SH LWLSMA PCMCIA SH LWLST PCMCIA SH LWLTOS PCM...

Page 4: ...2 RS 485 EIA 485 Interface SH RS485 PCMCIA 19 9 3 RS485AC Interface SH RS485AC PCMCIA 20 9 4 Twisted pair Interface SH TWP PCMCIA 21 9 5 Fiber Optic Interfaces SH LWLSMA PCMCIA SH LWLST PCMCIA SH LWLTOS PCMCIA 21 10 Troubleshooting 22 11Technical Specifications 23 11 2 CE Declaration of Conformity 25 11 3 Contact 25 11 4 Warranty 25 11 5 Support 25 11 6 Order information 26 11 7 Literature 26 4 ...

Page 5: ...rf nur in PCs mit Gehäusen gemäß EN 60950 1 eingebaut und betrieben werden 1 3 Elektromagnetische Verträglichkeit a An den ARCNET Anschlüssen dürfen nur geschirmte Kabel mit geschirmten Steckern angeschlossen werden b Es dürfen nur Bitraten verwendet werden die von SOHARD für das gewählte Übertragungsverfahren spezifiziert sind c Bei modularen Geräten dürfen nur originale Schnittstellenmodule von ...

Page 6: ... Bit breiten Datenbus Über ein geschirmtes Kabel wird ein Netzwerk Schnittstellen Modul angeschlossen Alle Netzwerk Schnittstellen Module befinden sich in einem Aluminium Gehäuse Bei Verwendung des ARCNET RAW Treibers sind die Geräte voll kompatibel zu den anderen SOHARD ARCNET Adaptern 3 Inbetriebnahme 3 1 Änderung von Busterminierung und Sendeleistung Bei allen Netzwerk Schnittstellen Modulen is...

Page 7: ... IO Basis 1 COM20022 Diagnostic Command IO Basis 2 COM20022 Address PTR HIGH IO Basis 3 COM20022 Address PTR LOW IO Basis 4 COM20022 DATA IO Basis 5 COM20022 RESERVED IO Basis 6 COM20022 Configuration IO Basis 7 COM20022 TENTID NODEID SETUP Die Funktion der Register ist dem Datenblatt 2 zu entnehmen 3 4 Einbau der Karte Die Karte ist eine Einbau Karte für Rechner mit PCMCIA Slot vom Typ 1 Externe ...

Page 8: ... Einstellung des Pulse1 Mode ist besonders bei Verwendung der RS485 Schnittstelle bei hohen Bitraten zu empfehlen 3 6 2 Zugriffsart Der COM20022 wird im Non Multiplexed Mode betrieben Die Umschaltung in diesen Modus erfolgt nach Reset durch einige Dummy Zugriffe auf den Baustein 2 Diese sollten von der Treibersoftware durchgeführt werden Beim Zugriff auf die empfangenen oder gesendeten Daten kann ...

Page 9: ... Rot Die LED zeigt alle Schreib Lese Zugriffe des Host PC auf die SH ARC PCMCIA Karte an Jeder Zugriff wird mittels eines digitalen Monoflops Zeitkonstante ca 1msec verlängert und so sichtbar gemacht 4 ARCNET Schnittstellen 4 1 Koaxiale Schnittstelle SH KOAX PCMCIA Anschluss BNC Buchse isoliert 4 2 RS 485 EIA 485 Schnittstelle SH RS485 PCMCIA Wichtiger Hinweis Zur Erhaltung der elektromagnetischen...

Page 10: ...le Die maximale Belastung darf 25 mA nicht überschreiten Schirm AGND Schirm AGND ist das Halteblechpotenzial GND_RS ist die Masse des galvanisch getrennten RS 485 Schaltungsteils Terminierung und Fail Safe Schaltung stellen sich wie folgt dar Der resultierende Abschlusswiderstand beträgt dabei ca 114 Ohm 10 RS485 Transceiver Pin3 Sub D Connector Pin4 Sub D Connector 240 Ohm 240 Ohm 150 Ohm S1 S2 5...

Page 11: ...ATA positive Datenleitung 5 DATA negative Datenleitung 1 3 6 9 unbeschaltet Reserviert 4 4 Twisted Pair Schnittstelle SH TWP PCMCIA Wichtiger Hinweis Zur Erhaltung der elektromagnetischen Verträglichkeit EMV muss das verwendete Kabel über einen Schirm verfügen der möglichst niederimpedant mit dem Steckergehäuse verbunden werden muss Anschluss RJ45 Buchse Belegung kompatibel zur SH ARC 66 von SOHAR...

Page 12: ...r Senden und Empfangen TX muss mit RX bzw RX mit TX der Gegenstelle verbunden werden Anschluss LWLSMA 2 FSMA Buchsen je eine für Senden und Empfangen TX muss mit RX bzw RX mit TX der Gegenstelle verbunden werden Anschluss TOSLINK Toshiba spezifische Buchse TODX296 für TX und RX Leitung Verwendbare Stecker TOCP200Q TOCP200X CF 2071 12 ...

Page 13: ...bindungen sind DATA A und DATA B vertauscht Die Koax Schnittstelle arbeitet nicht Mögliche Ursachen Der COM20022 arbeitet mit einer Bitrate kleiner als 2 5 Mbit s Der COM20022 befindet sich im Backplane Modus Karte läßt sich zwar ansprechen aber es kommt kein Datenverkehr zustande Mögliche Ursachen Bei RS485 Verbindungen sind DATA A und DATA B vertauscht oder die Terminierung ist nicht korrekt ein...

Page 14: ...Handbuch Manual 14 ...

Page 15: ...nd operated within PCs with casings according to EN 60950 1 6 3 To ensure Electro magnetic compatibility a Only attach shielded cables and shielded connectors to the ARCNET connector b Only use bit rates which are specified by SOHARD for the actual transfer mode c Only use original interface modules by SOHARD for modular cards d Only use PC casings with intact and complete shielding Unused slots m...

Page 16: ...in alloy casing When used with ARCNET RAW Drivers the devices will be fully compatible to the other SOHARD ARCNET adapters 8 Starting Up 8 1 Switching bus termination and transmission power By default the termination is switched off on all network interfaces If needed the termination can be activated by a DIP switch in all external interface modules On fiber optical network interface modules the t...

Page 17: ...DEID SETUP For functions of the registers see data sheets of COM20022 2 8 3 Installation of the card The cards are plug in cards for PCs with a PCMCIA slot type 1 A external network interface module must be connected to the SH ARC PCMCIA card 8 4 Device drivers and alternative access Device drivers ARCNET driver and descriptions for their installation and usage are to be found on the enclosed CD P...

Page 18: ... dummy accesses 2 after reset As a rule the correct setting is already effected by accesses to the PC to other I O units such as graphics card or serial interfaces We nevertheless recommend to carry out these accesses in the driver software The COM20022 must be operated in the 8 bit mode corresponds to COM20020 8 6 LED s on network interface module LED Description Green The LED reports all activit...

Page 19: ...lectro magnetic compatibility EMC the shield of the cable connected to the D sub DE9M plug must be solidly attached to the screen of the connector Connector type D sub DE9F socket Pin assigment Pin Marking Description 1 5 GND_RS Reference potential supply 3 DATA A Data line A 4 DATA B Data line B 2 6 8 NC reserved 9 5V_RS Isolated 5 V Supply for RS485 Interface The maximum current must not exceed ...

Page 20: ...ty EMC the shield of the cable connected to the RJ45 plug must be solidly attached to the shield of the connector Connector type RJ45 socket Pin assignment Pin Marking Description 4 DATA Data line 5 DATA Data line 1 3 6 9 NC Reserved 20 RS485 Transceiver Pin3 Sub D Connector Pin4 Sub D Connector 240 Ohm 240 Ohm 150 Ohm S1 S2 5V RS485 GND RS485 RS485 Terminierung ...

Page 21: ...Pin Description 4 PH_A Data line 5 PH_B Data line 1 3 6 9 NC Reserved 9 5 Fiber Optic Interfaces SH LWLSMA PCMCIA SH LWLST PCMCIA SH LWLTOS PCMCIA LWLST connectors 2 x ST BFOC bayonet for transmission and reception respectively Connect TX to RX and vice versa LWLSMA connectors 2 x FSMA threaded for transmission and reception respectively Connect TX to RX and vice versa TOSLINK connector TOSHIBA sp...

Page 22: ...ons Possible causes only one node in network network is incorrectly configured DATA A and DATA B mixed up at RS485 connections Coax interface does not work Possible causes wrong bitrate i e 2 5 Mbit s backplane mode is activated Card responds but no data traffic Possible causes DATA A and DATA B mixed up at RS485 connections or incorrect termination optical transmit power too low or too high overl...

Page 23: ...id bit rate and transmission mode 19 531 39 063 78 125 156 25 312 5 625 kbit s 1 25 2 5 5 10 Mbit s 11 1 3 Coaxial Interface K Data rate Input impedance Input threshold Line termination Output peak voltage Output signal shape Cabling Connector 2 5 Mbit s 10 kohm at f 5 MHz 2 5 Vpp 93 ohm no internal termination min 16 V on terminated 93 ohm line Sine dipulse 200 ns according to 1 RG62 with Z 93 oh...

Page 24: ...et 11 1 6 Twisted pair Interface TWP Data rate Bus termination Output peak voltage Ouput pulse shape Cabling Connector 2 5 Mbit s 120 ohm internal termination disabled by default min 16 V on terminated 93 ohm line Sine dipulse 200 ns according to 1 Twisted pair wire with Z 120 ohm is recommended Shielded RJ45 socket 11 1 7 Optic Fiber Interfaces ST and SMA LWLST LWLSMA Data rate Optical input powe...

Page 25: ...lacement on the market in the European Economic Area CE marking The declarations of conformity may be requested under info sohard de 11 3 Contact Address SOHARD Embedded Systems GmbH Wuerzburger Str 197 90766 Fuerth Germany Tel 49 0 911 97341 522 566 Order management Technical support Fax 49 0 911 97341 510 eMail info sohard de 11 4 Warranty Warranty is granted by SOHARD Embedded Systems according...

Page 26: ...C coaxial cable RG 62 SH LWLSMA PCMCIA 0 156 2 5 Light FSMA multi mode fibers SH LWLST PCMCIA 0 156 2 5 Light ST BFOC multi mode fibers SH LWLTOS PCMCIA 0 156 2 5 Light TODX296 TOSLINK multi mode fibers SH RS485 PCMCIA 0 156 10 RS 485 D Sub twisted pair cable SH RS485AC PCMCIA 2 5 10 RS 485 RJ45 twisted pair cable SH TWP PCMCIA 2 5 sine dipulse RJ45 twisted pair cable 11 7 Literature Reference Doc...

Page 27: ...Handbuch Manual 27 ...

Page 28: ...Handbuch Manual 28 ...