** 6” will be refreshing every press of “delay” button.
During the first 6” of test, if a failure code is stored in memory, its codification is shown.
-
When “Service test” routine is recognized, “Service test” is shown on the LCD and Service test starts.
It will be possible to see last 6 faults by pressing “Delay” button.
To cancel this mode and return back the normal usage condition, machine must be
switched OFF
. When machine switched
ON again it is now in ready condition to select and start a new program.
8
.2.3. SERVICE FAILURE CODES TABLE
Name
TEXT
Notes
Overflow
Water Overflow
In the normal work this failure is not
visualized.
Leakage
Water Leakage
Draining time out
Drain failure
Presence of Flow meter
impulses
Water input
Absence of Flow meter
No Water Impulse
In the normal work this failure is not
visualized.
Empty Level
Inadequate water
Re-Fill time out
Inadequate water
NTC ca/cc
Heater sensor
Overheating
Over Heating
Unsuccessful heating
No Heating
Diverter opened
Diverter Failure
Turbidity Sensor
Turbidity Sensing
In the normal work this failure is not
visualized.
Parameter set salt incorrect
Salt Set Failure
In the normal work this failure is not
57