Test Mode 

 

4.1. 

     Autotest 

 

* This test is for quick checking of the product. You can not see the 
failure codes. 

 

1. 

Push  SW4  button.  Keeping  SW4  button  pushed,  turn 

program knob to position 1. 

 

 

 
 

 

 

 

 
 
 
 
 

2. 

After  3  sec,  door  will  be  locked  and  machine  enters 

autotest  mode.  Release  SW4  button.  "AU"  will  be 
visualized on LCD. 

 
               The test steps are as below; 
                

Step1: 

 The  pump  is  activated  for  3  seconds  and  there  is  EPS 

check  ,  the  frequency  value  should  be  between  the  46.04Hz  and 
43.40Hz. It checks the EPS and if it is OK it continues the autotest; if 
it  is  NOK  then  it  should  give  E10  ERROR  &  cancels  the  autotest  ( 
goes  to  the  selection  mode  ).  Also  if  any  frequency  can  not  be 
detected, then it means there is problem with connection or EPS, so 
it gives E10 which is EPS error and cancels the autotest.     
            

Step2:

   The  motor  ramps  to  max  spin  for  15  seconds.  While  its 

speed  rising  up  to  the  maximum  speed  the  EV1  (prewash  valve)  is 
activated  for  5  seconds  and  then  the  EV2  (wash  valve)  is  activated 
for 5 seconds. 
                

Step3:

   The  motor  reduces  speed  to  stop  (depends  on  the  motor 

stop  time)  for  5  seconds.  While  it  is  slowing  down  it  activates  EV1 
and EV2 valve, concurrently. 
                 

Step4:

   The motor turns to right. 

                

Step5: 

  The motor turns to left for 5 seconds. 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
Step6:

  

The option 1 button is pushed  

 

The  EV1  and  EV2  are  activated  concurrently  until  it  reaches 
pressure sensor's first level frequency ( Hz ) for 5 seconds. 
 

Step7:

   Software will detect NTC's resistance value and will check 

if the temperature is between 5°C < Tdetected < 40°C . If it is inside 
the range, heating step  will  be  done. If temperature  value  is  outside 
the  range,  then  it  means  NTC  is  detecting  the  temperature  in  a 
wrong way and heating step will be skipped. 
                

Step8:

   Autotest ends and "--" is visualized (T0).

 

Autotest  ends  and  "End"  is  visualized  on  LCD  (In  the  rest  of  the 
models). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for T0 Series

Page 1: ...S rie T0 CODES PANNES et AUTOTEST...

Page 2: ...eans 14 Daily 60 15 Rapid 15 16 OFF Mix algoritm is available for 32 40 41 42 44 44 47 49 50 54 59lts Duvet algorithm is available for 55 60 61 62 lts Rapid 15 is available for without twinjet model R...

Page 3: ...L is visualized on display for 2 sec to indicate child lock activation with tone D buzzer in models having buzzer option After 2 sec CL indication if fixed off and remaining time is visualized on disp...

Page 4: ...ramps to max spin for 15 seconds While its speed rising up to the maximum speed the EV1 prewash valve is activated for 5 seconds and then the EV2 wash valve is activated for 5 seconds Step3 The motor...

Page 5: ...8 Flow chart of the autotest During test AU is visualized on display at the end of the test is visualized and door is unlocked During test pressing other buttons makes no change on display...

Page 6: ...till first level frequency then start heating Heater will be on max 8 minutes If temperature doesn t increase 2 C in 8 minutes machine will give NTC failure E05 Or if the NTC connection is broken the...

Page 7: ...ation Error Number Indication For User Indication For Service Yes No Yes No Door is not locked E01 Yes Yes Door is unlocked during programme E01 Yes Yes Lack of water E02 Yes Yes Pump failure E03 Yes...

Page 8: ...y in the next washing process Wrong detergent has been used Use only the detergents produced for full automatic machines The washing result is bad Laundry too dirty for the program you have selected S...

Page 9: ...intanance pump filter should be cleaned regularly 8 1 1 Technical Features Nominal voltage 220 240 V Nominal current 0 28 A 10 Nominal power 37 W Frequency 50 Hz Resistor coil 130 5 Water flow 17 L mi...

Page 10: ...ctions Phase notral and ground connections 8 2 1 Technical Features Kind of heating Tubular heating element with NTC sensor Nominal voltage 230 V Nominal power 2000 W 5 Resistance 24 8 5 Thermal fuse...

Page 11: ...6 5 43 0 48 6 0 33 9 38 1 5 27 0 30 1 10 21 6 23 9 15 17 4 19 1 20 14 1 15 4 25 11 5 12 5 30 9 4 10 2 35 7 8 8 3 40 6 4 6 9 45 5 4 5 7 50 4 5 4 7 55 3 8 3 9 60 3 2 3 3 65 2 7 2 8 70 2 3 2 4 75 1 9 2 0...

Page 12: ...res Nominal voltage 220 240 V Nominal power 8 VA Frequency 50 60 Hz Rated flow 7 lt min 15 Operating water pressure 0 0 3 1 Mpa 8 4 2 Checking of Component Check the resistance value on the component...

Page 13: ...of Component 1 Make sure there are no laundry in washing machine tap is connected and opened power cord is plugged Put no detergent in drawer 2 Bring porgram knob to position 1 Cotton 90 C program 3 P...

Page 14: ...It is essential to check the motor for correct diagnosis and quick servicing In the below picture socket points on the motor is shown to measure with multimeter Motor Socket Terminals Tacho Socket Te...

Page 15: ...32079 TONLON 2 28 7 NA 70 2 7 32030653 G J 2 28 2 63 NA 60 69 69 83 32037679 KENING 2 10 7 NA 63 6 7 32031043 G J 2 03 2 34 NA 60 69 69 83 32027577 WELLING 2 39 7 NA 66 6 7 32027576 HAIER 2 36 7 NA 68...

Page 16: ...TC which is assambled in the door lock 8 7 1 Technical Features Lock Time 20 C 2 6 Unlock Time 20 C 35 75 Nominal voltage 220 V Nominal current 16 4 A 8 7 2 Checking of Component Check the resistance...

Reviews: