E04
Overflow
Do not run WM till enviromental conditions in
product specifications are met
Refit loose sockets/connectors, replace cable
group if connectors/sockets are worn
Replace pressure
switch/sensor hose
Replace pressure
switch/sensor
Are environmental
conditions are OK?
Check PCB socket
connections. Is thee any
loose socket/connector?
Similarly check pressure
switch/sensor and valve
connectors. Is it loose?
Is there any deformation
through pressure
switch/sensor hose?
Test pressure switch/sensor
component as explained in
service manual. Is pressure
switch/sensor component OK?
Replace PCB
NO
YES
Environmental conditions:
-Voltage range should be in as specified
in instruction book.
-Water pressure should be as specified
in instruction book.
-WM should be grounded properly.
-There should be enough ventilation
space from ground.
-Other environmental specifications and
requirements should be met which are
mentioned in instruction book of WM.
Replace valve
Does WM intake water
when power is off?