background image

 

 

 

SERVICE MANUAL 

 

7.8.1. Cooling Fan Measurements 

 

 
 
 

 
 
 
 
 
 
 

 

7.9. Drumlight 

 
 
 
Drumlight lights inside of the drum 

 
 
 
 

Component Test 

Check whether there is electrical transmission from IDC connected to electronic card. 

 

BANDEAU 

HP F2

Summary of Contents for BANDEAU HP F2

Page 1: ...SECHE LINGE MANUEL DE SERVICE BANDEAU HP F2 ...

Page 2: ...Drying Stages Indicator 4 2 Program List KNOB POSITION PROGRAM 1 Cotton Extra Dry 2 Cotton Cupboard Dry 3 Cotton Iron Dry 4 Synthetics Cupboard Dry 5 Synthetics Iron Dry 6 Delicate 7 Mix 8 Baby Care 9 Jeans 10 60 min 11 40 min 12 20 min 13 Refresh 14 Express 45 15 Shirts 30 16 OFF BANDEAU HP F2 ...

Page 3: ...e washing machine are dried in 45 minutes Shirts 30 2 to 3 shirts are ready for to be ironed in 30 minutes Delicate Delicate fabrics are dried for a longer time at a low temperature 4 3 Children s Safety There is a child lock option to avoid changes in the program flow when keys are pressed during the program There is a child lock option to avoid changes in the programme flow when keys are pressed...

Page 4: ...uto test must be run for every service call The case in the photo don t show us a failure code Normally when the drying program ends the filter water tank and end led are flashing In addition heat exchanger cleaning warning led is on every 30 cycles BANDEAU HP F2 ...

Page 5: ... led makes slow blink to indicate that service can pass the next step For error codes leds must make fast blink ERROR CODE REASON E03 Aquaswitch connector is disconnected E04 Compressor connector is disconnected E05 Compressor NTC connector is disconnected E06 Door NTC connector is disconnected E07 Motor connector is disconnected motor is locked E08 Voltage fluctuation F2 HEAT PUMP MODEL ERROR COD...

Page 6: ... not Knob Motor CCW Tumble CW Motor stops Motor connector is taken out Position 4 Motor might be locked Motor belt might be dislocated Step 5 Service must check whether tumble is moving to CCW Knob Motor CW Tumble CCW Motor stops If tumble is moving to CW again then motor relay Position 5 short circuit CCW Step 6 Check Compressor NTC if heater NTC Compressor NTC connector is taken out or short Kno...

Page 7: ...or speed 2750 rpm Unloaded drum Drum speed 52 2 Capacitor value 11 µF 5 Component Test Check whether the motor cable is connected to the motor connector Check the connection of the capacitor cables Measure the resistance values and check the capacitor values Check whether it is working by connecting via the terminals 1 and 2 Blue White connection If it is working revolution of the drum is measured...

Page 8: ...SERVICE MANUAL 7 1 1 Motor Measurements 1 2 3 2 1 3 3 1 2 BANDEAU HP F2 ...

Page 9: ...0 240 Volt Frequency 50 Hz Input Power 13W max Component Test Check the connection of the pump connector Check the pump resistances Check whether pump is working by feeding externally If the pump is working the water in the tank is unloaded by running the pump Then Unload 500 ml of water from water tank to pump reservoir and check whether water is pumping While pump is working if water is not reac...

Page 10: ...SERVICE MANUAL 7 2 1 Pump Measurements 2 1 1 BANDEAU HP F2 ...

Page 11: ...e inserted 7 4 Door Compressor NTC Sensor Two NTC sensors are used The NTC resistance decreases when the temperature rises Technical Features Door NTC Resistance 12 kΩ Measured from IDC connected to electronic card Compressor NTC Resistance 12 kΩ Measured from IDC connected to electronic card Component Test Resistance is measured from IDC connected to electronic card BANDEAU HP F2 ...

Page 12: ...on the right the terminal on the compressor are shown to be measured by multiple counters It is driven with relay via the electronic card to give energy and relay drive the compressor only one direction Technical Features Type single phase asynchronous motor Power 350 W Unloaded drum Main windings 9 3 7 25 C temp 2 1 1 BANDEAU HP F2 ...

Page 13: ...ection of the capacitor cables Measure the resistance values and check the capacitor values Check whether it is working by connecting via the terminals S R and C connection If it is working start the machine and check the drum temperature The terminals S and R of the motor should be connected with capacitor Resistance measurement of main winding Terminal C R is measured Resistance measurement of a...

Page 14: ...SERVICE MANUAL 7 5 1 Compressor Measurements 2 1 3 c r s r c s c s r BANDEAU HP F2 ...

Page 15: ...ed to be opened from inside in case of children are in the drum Component Test When the door is closed check whether there is electrical transmission from IDC connected to electronic card Check the connection of the component connector 7 6 1 Door Latch Measurements 2 1 BANDEAU HP F2 ...

Page 16: ...nt of dryness of the laundry in the drum Component Test Each humidity sensor plate is checked whether there is electrical transmission from IDC connected to electronic card Check the connection of the component connector 7 7 1 Humidity Sensor Measurements 2 1 BANDEAU HP F2 ...

Page 17: ...ssor are shown to be measured by multiple counters It is driven with triac via the electronic card to give energy Technical Features Type single phase AC fan Power 28 W Main windings 600 7 Motor speed 2600 3000 10 Component Test Check whether the cooling fan cable is connected to the fan terminal Measure the resistance values BANDEAU HP F2 ...

Page 18: ... MANUAL 7 8 1 Cooling Fan Measurements 7 9 Drumlight Drumlight lights inside of the drum Component Test Check whether there is electrical transmission from IDC connected to electronic card 2 1 1 BANDEAU HP F2 ...

Page 19: ...he Main Board MACHINE IS NOTWORKING Is Electricity Reaching To Main Board YES YES Change the cable tree NO NO Machine has not a failure Is The Supply Cord Plugged Into The EMI Filter NO Make Electrical Connection YES Is the current transmitted on supply cord plug YES NO Change the supply cord and plug BANDEAU HP F2 ...

Page 20: ...h correct YES YES Fix the position of the switch NO NO YES Close Repair the door Is the door latch socket connection correct NO Make Electrical Connection YES Check the door latch with multimeter for short circuit YES NO Change the door latch Is the door latch cable transmitted the current Change the door latch cable NO YES BANDEAU HP F2 ...

Page 21: ...rum rotating CW Change compressor NTC Change the compressor Check the drum is not rotating alg NO YES YES YES YES NO NO NO NO Is machine power correct YES NO Check the compressor gas YES Is the Filter and Condenser Clean Clean Filter and or Condenser NO NO Make Electrical Connection Are the measured resistance values through the Comp NTC Correct Is the compressor cable transmitted the current to e...

Page 22: ...nge The Motor Is Right and Left Wheel Rotating Check If Rear Isolation Group Is Stable Check If Front Isolation Group Is Stable Is Bearing Group Spherical Bearing stable and Solid Is Drum as It Should Be Bearing Shaft Curling Rivet Is Drum Pressed By Side Panel Or Base Plastic Change The Drum Wheels may be stuck or damaged Replace the wheels Replace Bearing Group Change Rear Isolation Group Change...

Page 23: ...Check the compressor gas YES Change the cable tree User should be informed about the machine YES NO Is connection of compressor connector correct Are the measured resistance values through the compressor connector correct E08 ERROR Is the voltage in the socket between 170 265 V Change The Main Board YES Machine has not a failure The power line should be checked NO BANDEAU HP F2 ...