MedDream (version 8.0.0)  

INSTALL MANUAL 

of MedDream video viewing 

and converting functionalities 

version 4.6.1 

 

Summary of Contents for MedDream

Page 1: ...UAB Softneta K Barsausko st 59 LT 51423 Kaunas Lithuania info softneta com www softneta com MedDream version 8 0 0 INSTALL MANUAL of MedDream video viewing and converting functionalities version 4 6 1...

Page 2: ...products Other brand names software and hardware names used in this user s manual is subject to trademark or patent protection The quoting of products is for informational purposes only and does not r...

Page 3: ...16 Settings 17 General settings 17 Network settings 18 Recording settings 20 Device settings 22 Recording configuration settings 25 Stream settings 27 Storage disc space and service management 31 Auto...

Page 4: ...ily workflow and on the device labels WARNING This indicates a hazardous situation which may cause patient death potential injury or serious health impairment requiring professional medical interventi...

Page 5: ...settings It is recommended to select close enough or the same resolution for medical device output signal to ensure best quality Use WIDTH and HEIGHT entry controls to adjust the selected size or ent...

Page 6: ...m play video and take snapshots at the same time Record video take images from multiple connected devices special video card needed Flexible patient data assignment selecting already existing patient...

Page 7: ...SS HTML JavaScript built applications JAVA WEB server and MySql database So all data is stored into MySql database program configurations are saved into files and studies are stored as image video DIC...

Page 8: ...Intel Media SDK installation here C MedDreamStation software README md To install software for the first time follow steps bellow NOTE VS use 80 3310 8081 4568 ports for main applications to work Oth...

Page 9: ...ct the components you want to install clear the components you do not want to install Select Language which you want to install And click next when you are ready to continue Figure 5 Select components...

Page 10: ...onnections 6 VS setup display information about installing software To start installation click Install Figure 7 Ready to install page 7 Wait while setup installation complete copy files install and s...

Page 11: ...Follow 1 3 steps from To install software for the first time section 2 Installation setup ask you select which components should be installed We recommend leave all components checked Click Next Figu...

Page 12: ...ect current root password first field or must start VS services If you really know that the password is correct and can t run workstation services press Yes button to continue installation Figure 12 B...

Page 13: ...ss page 6 Complete VS installation Figure 15 VS success installed Software uninstalls 1 To uninstall software go to Control or Settings and select Uninstall Figure 16 Programs and Features VS file for...

Page 14: ...uninstall VS software 4 Windows let you know when uninstall process complete After uninstall remains these files and information license DICOM image video and settings files They should be deleted ma...

Page 15: ...PLAY STOP KEY are set but it is recommended to review and update key combinations for every pedal Can add multiple key combinations all pedals for snapshot or video recording as long as they do not co...

Page 16: ..._IR 144 Cyrillic or ISO_IR 192 UTF 8 To support most of the characters use ISO_IR 192 But it is recommended to consult to your DICOM archive PACS administrator NOTE Try to set the same character set f...

Page 17: ...can be checked by pressing button will send DICOM C ECHO to verify basic connectivity by DICOM protocol Once all settings are set double check and press save button REMOTE hospital remote DICOM archiv...

Page 18: ...otocol common use is 104 or 11112 ports Recommended to consult administrator CHARSET setup encoding for worklist results Result comes in DICOM standard and most results do not define encoding need to...

Page 19: ...amera to profile A and the same camera to profile B and enabled both of them to be active in VS application In this situation just profile A will start and profile B will fail because input signal wil...

Page 20: ...PACS DICOM conformance statement document and recorder DICOM files will be accepted by PACS Some options can be updated in C MedDreamStation recorder configurationSettings json but during re installa...

Page 21: ...ard input type and select the correct one AUDIO INPUT specify how to get audio signal This option depends on device input or device itself For example default selection EMBEDDED should work with simpl...

Page 22: ...TION VS software will try to scale medical device output signal to match settings It is recommended to select close enough or the same resolution for medical device output signal to ensure best qualit...

Page 23: ...vices 1 2 840 10008 1 2 4 102 and 1 2 840 10008 1 2 4 102 MPEG 4 video options for most of devices 1 2 840 10008 1 2 4 102 and 1 2 840 10008 1 2 4 103 MPEG 4 video with strict combination options NOTE...

Page 24: ...her following option ADM VCE INTEL MEDIA SDK requires install Intel media SDK NVIDIA CUDA NVIDIA ENVENC Customize video compression by setting the parameters ENCODER FORMAT set available encode format...

Page 25: ...t AUDIO CHANNELS set available channels AUDIO BITS set available bits AUDIO FREQUENCY set available frequency AUDIO BIT RATE enter bit rate value The higher bit rate means the higher quality AUDIO VOL...

Page 26: ...mat for stream output COLOR SPACE set available color space for the stream output Figure 38 Stream output options in the Recording profile Stream settings VIDEO IMAGE SIZE set available video resoluti...

Page 27: ...best quality encoding for VBR encoding mode The default value is 8500 ENCODING BIT RATE enter bit rate value for CBR encoding mode The higher bit rate means the higher quality Default value is 838860...

Page 28: ...er bit rate means the higher quality Default value is 131072 AUDIO VOLUME enter audio volume from 0 to 100 percent The default value is 100 percent Figure 41 Real Time Streaming Protocol RTSP options...

Page 29: ...ee DELETE IF DISK SPACE IF LOWER THAN GB when to trigger auto delete function at VS application startup on computer startup starting application NOTE If parameter DELETE IF DISK SPACE IF LOWER THAN GB...

Page 30: ...on button requires to activate ENABLE AUTO DELETE Manual deleting Manual deletion main idea to delete all studies that is created between date range To delete the studies apply the following steps In...

Page 31: ...and the information message is displayed on the screen If the status cannot be changed the error message is displayed on the screen In such cases you should fix an error for example go to the network...

Page 32: ...icense Functional test When the physical and software installation is completely done we recommend do some tests before start working Making sure everything works smoothly Create new study To create n...

Page 33: ...JAVA background application This will ensure just one active client WebSocket is also restricted by IP address Password During MedDream VideoStation installation will offer to enter passwords for roo...

Page 34: ...free There is the case that some modern cameras do not support standard Windows DirectShow API or requires device special dedicated software to run the device probably installed as a virtual devices...

Page 35: ...16 Figure 20 VS settings 16 Figure 21 VS general settings 17 Figure 22 Shortcuts for recording and image making 18 Figure 23 Shortcuts for recording and image making 18 Figure 24 Local VS settings 19...

Page 36: ...1 Real Time Streaming Protocol RTSP options in the Recording profile Stream settings 30 Figure 42 Storage settings 31 Figure 43 Auto deletion settings 32 Figure 44 Manual deleting settings 33 Figure 4...

Page 37: ...ord 35 Physical installation 9 R Recording configuration settings 25 Recording settings 20 S Security considerations 35 Service 33 Settings 17 Software installation updates 10 Software uninstalls 15 S...

Page 38: ...dDream is manufactured by Softneta UAB Medical device class Regulation EU 2017 745 Class IIb medical device FDA cleared ID of the notified body 0197 Document version 1 0 Date of issue 2022 08 04 Langu...