cfg#sid 4 130551477
Sensus ID[4] changed from : 0 to : 130551477
mon#
Current list of read watermeters is stated in the list of all configuration parameters. The list can be also displayed
by using of ”sid” command without parameters:
cfg#sid
Sensus
ID[0] 76738781
ID[1] 76738783
ID[2] 76738791
ID[3] 0
. . .
ID[18] 0
ID[19] 0
mon#
The table allows entering up to 20 watermeters. The ID value is used as an index in the outgoing message. The
watermeter can be removed from the list by entering the value ”0” for the given index.
The third group of commands
serves for setting of reading data from watermeters in
”WMBUS” mode
(for devices transmitting in Wireless M-Bus format). There are following commands:
wkey [index] [value]
setting of encryption key for decrypting of watermeter messages
sid [index] [value]
setting of watermeter IDs for reading (reading list)
dib1 [index] [value]
setting of DIF and VIF for selection of the first variable
dib2 [index] [value]
setting of DIF and VIF for selection of the second variable
diba [index] [value]
setting of DIF and VIF for selection of alarm variable
alrb [index] [type] [value]
assigning the alarm type to the alarm flag value
The command
”WMBUS encryption key”
is used for setting of the encryption key for decryption of messages
from individual watermeter (if its messages are encrypted). The AES-128 encryption key of 16 bytes length is entered
by using of
”skey”
command, followed by the string of 16 bytes that can be entered in a decimal or hexadecimal
format same way as encryption key for NB-IoT communication (see using of ”ekey” command in paragraph
below).
The
”Set Meter ID”
variable serves for setting of list of watermeters, that is intended to be read by the NB-K868
module. Each record to the list could be created by using of
”sid [index] [value]”
command, where meter ID
(serial number) is linked with meter index (0 - 9). Example of command for entering of watermeter with ”76738781”
serial number into the list of read meters under index ”0”:
cfg#sid 0 76738781
WMBUS ID[0]
changed from : 0 to : 76738781
cfg#
Current list of read watermeters is stated in the list of all configuration parameters. The list can be also displayed
by using of ”sid” command without parameters:
mon#sid
cfg#sid
WMBUS
ID[0] 76738781
ID[1] 76738783
ID[2] 76738791
ID[3] 76738795
ID[4] 0
. . .
ID[18] 0
ID[19] 0
mon#
NB-K868
14