mon#?
--- System commands ---
deb
: Show or set debug level
ta
: Show tasks
mb
: Show mail boxes
du addr
: Dump memory
rb addr
: Read byte from addr
rw addr
: Read word from addr
rd addr
: Read dword from addr
sb addr val
: Set byte on addr
sw addr val
: Set word on addr
sd addr val
: Set dword on addr
port
: Show port [a,b,..]
show
: Show info
write
: Write configuration to flash
cread
: Read configuration from flash
clear
: Clear configuration and load defaults
---
433 commands --- ---
power
: Show or set 433 power (1 - 5)
mr
: Modem receive mode 0 - off, 1 - on
mt test time
: Set test on modem, 1 - TX carrier, 2 - TX sync, time is in second, default 10
ms
: Get modem state
mi
: Get modem info
recvwin
: Set receive window in sec.
radar
: show radar
hdata
: show history data
--- Narrow band ---
server
: Server IP address
sport
: Server UDP port
sreply
: Send reply to server
apn
: Access Point Name
sess
: Set max session time in minutes
tshort
: Set modem short timeout
tlong
: Set modem long timeout
tconn
: Set modem connection timeout
at
: modem command
--- Utils ---
tz
: Time offset in hours
ppm
: Set RTC ppm
time
: Show or set rtc time, set as BCD : 0x102033 is 10:20:33
date
: Show or set rtc date, set as BCD : 0x171231 is 2017-12-31
uptime
: Show uptime
sens
: Show sensors
mfreq
: Set or get xtal frequency correction
sfreq
: Set frequency correction from analyzer in Hz, example : 433725000
cfreq
: Set +- frequency correction, 1 = 1Hz
sendp
: Send x NB messages
send
: Send NB message
smask
: Send mask bits, 0 - SID, 1 - Alarm, 2 - RSSI ,default 7 - all
periode
: Change periode of send
0 - disable, >0 periode in minutes
hist
: History periode 0 - disable, >0 periode in minutes
ekey
: Set encrypt key NEP, point ’.’ no encrypt
skey
: Set encrypt key Sensus
sid [index] [value] : Set Sensus meter ID
info
: Show or set manuf. info string (0-30 chars)
reset
: Reset device
?
: Show this help
Overview of configuration parameters with short description of their meaning can be also found in table
on the
page
. The meaning of individual parameters and detailed description of their usage can be found below.
NB-K430