TESTING VIDEO CABLES
1. Connect the provided F-Connector coupler to the F-Connector at the top of the
main tester (see Figure 6 below).
Figure 6. F-Connector on Main Tester
2. Screw one end of the video cable into the F-Connector coupler.
3. Secure a Coax remote to the opposite end of the video cable.
4. Press the VIDEO MODE button to start continuous testing. The following updates
appear in the LCD display screen (see Figure 7):
• The “Video” icon illuminates in the upper right corner.
• A progression of “o’s” appear on the bottom of the display to indicate active
testing.
• The cable wiring structure displays (Pass, X-over, or Rev).
• The “ID” icon appears with the Coax wire mapping remote number to its right.
Figure 7. Loop Testing in Video Mode
Note: The tests run until the O/ID button is pressed or when 5 minutes elapses with no
change in the test results.
5. Trouble-shoot if cable faults (open or short) are detected.