Individual tests
1
2
Function keys
6.2
Copper media
The following tests are available for copper media.
Note: PoE is only available for twisted pair cabling.
6.2.1
Wiring diagram
1
2
3
Function keys
The wiring diagram is given per pin, the length per pair. The shortest
length is shown in the report as link length.
With
Set Reference
the reference plane for the length measurement
can be set.
If the first patch cable is to be included in the length calculation,
Set
Reference
should be performed WITHOUT the patch cable. If the first
patch cable is not to be included in the length calculation, the cable
must be connected at
Set Reference
.
Function keys: (Only in Tools mode)
1. Back one menu level higher
2. Change wiring diagram settings
You can adjust the following
a. color scheme of the wiring diagram
b. 2 or 4 pair measurement
c. Use of crossed cables
d. Use of a cable shield
e. Set or determine NVP value
3. Start new test