SFT3316 16 in 1 IP QAM Modulator User Manual
8
Chapter 4 Web NMS Management
User can only control and set the configuration in computer by connecting the device to web
NMS Port. User should ensure that the computer’s IP address is different from this device’s IP
address; otherwise, it would cause IP conflict.
4.1 Login
The factory default IP address please check the rear panel of the device (Usually
1.0.0.101/102/103), if no IP address on rear panel, the default IP address should be
192.168.0.136, and users can connect the device and web NMS through this IP address.
Connect the PC (Personal Computer) and the device with a net cable, and use ping command to
confirm they are on the same network segment. For instance, the PC IP address is
192.168.99.252, we then change the device IP to 192.168.99.xxx (xxx can be 0 to 255 except
252 to avoid IP conflict).
Launch the web browser an input the device IP address in the browser’s address bar and press
Enter.
It will display the Login interface as Figure-1. Input the Username and Password (Both the
default Username and Password are “admin”.) And then click “Login” to start the device setting.
Figure-1
4.2 Operation
4.2.1 Summary
When we confirm the login, it will display the summary interface as Figure-2 where users have an