HYD 5-20KTL-3PH
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
。
- 59 -
failure
ID135
unrecoverIacUnb
alance
Permanent failure of
unbalanced
output
current
ID137
unrecoverPvConf
igError
Input mode setting error
permanent failure
Check
the
PV
input
mode
(parallel/independent mode) Settings for the
inverter. If not, change the PV input mode.
ID138
unrecoverPVOCP
Instant
Input
overcurrent
permanent fault
ID139
unrecoverHwPV
OCP
Input
hardware
overcurrent permanent
failure
Internal faults of inverter, switch OFF
inverter, wait for 5 minutes, then switch ON
inverter. Check whether the problem is
solved.
If no, please contact technical support.
ID140
unrecoverRelayF
ail
Permanent relay failure
ID141
unrecoverVbusU
nbalance
Bus voltage unbalanced
permanent failure
ID145
USBFault
USB fault
Check the USB port of the inverter
ID146
WifiFault
Wifi fault
Check the Wifi port of the inverter
ID147
BluetoothFault
Bluetooth fault
Check the bluetooth connection of the
inverter
ID148
RTCFault
RTC clock failure
Internal faults of inverter, switch OFF
inverter, wait for 5 minutes, then switch ON
inverter. Check whether the problem is
solved.
If no, please contact technical support.
ID149
CommEEPROM
Fault
Communication board
EEPROM error
ID150
FlashFault
Communication board
FLASH error
ID153
SciCommLose(D
C)
SCI
communication
error (DC)
ID154
SciCommLose(A
C)
SCI
communication
error (AC)
ID155
SciCommLose(F
use)
SCI
communication
error (Fuse)
ID156
SoftVerError
Inconsistent
software Contact for technical support and software