SOFAR 7.5KTLM
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
- 47 -
Enable this option before setting the country.
Attention: when inverter working for power generation over 24h, country
setting is forbidden, it can only be set after LCD setting. Key in passwords for
country setting through LCD (default: 0001), country setting can be set in 24h after
keying in the correct passwords, over 24h, set through LCD again.
7. Set Energy
Set the total power generation. You can modify the total power generation
through this option.
8. Set address
Set the address (when you need to monitor multiple inverters simultaneously)
,
Default 01.
9. Set Input mode
Input mode selection: SOFAR 7.5KTLM inverter has 2 MPPT channels,which
can run independently or in parallel.Users choose the operation mode of MPPT
according to the system design.Parallel mode is applicable to the case where two
channels are in parallel, independent mode is applicable to the case where two
channels of MPPT run independently, and the default mode is independent mode.
10. Set Language
Set the inverter display language.
Easier Way: press
“
Back
”
&
“
OK
”
at the same time to change system
language.
11. Set Start Parameter
12. Set Safety Voltage
13. Set Safety Frequency
14. Insulation Resistance
User can modify the above 4 parameters of the machine through the SD card,
and the user needs to copy the parameter information that needs to be modified into
the SD card in advance.
Note:To enable this feature, please contact the Sofarsolar technical support .
15. Set Reactive