socomec SIRCO PV Manual Download Page 6

IS 542123-B

6/6

Non contractual document - Document non contractuel - Documento no contractual

600Vdc : 98B, CSA C22.2 Nr. 4, IEC 60947-3 (grounded) [one pole per circuit]

UL 100A - 250A

IEC 100A - 315A

UL 275A - 400A

IEC 275A - 500A

600Vdc : 98B, CSA C22.2 Nr. 4, IEC 60947-3 (grounded) [one pole per circuit]

1000Vdc : 98B, IEC 60947-3  -  600Vdc : CSA C22.2 Nr. 4 [2 poles in series per circuit]

Grounded

Grounded

Grounded

Ungrounded

Ungrounded

Ungrounded

 27PV5009
 26PV5010
 27PV5019
 26PV5016
 27PV5024
 26PV5025
 26PV5031
 27PV2011
 27PV2021
 27PV2026

 27PV6026
 27PV6032

     27PV6039

 27PV2028
 27PV2033
 27PV2042
 27PV3027
 27PV3033
 27PV3042
 27PV8026
 27PV8032

     27PV8039

   27PV4027
   27PV4033
   27PV4042

Grounded

Ungrounded

1500Vdc : IEC 60947-3  - 1000Vdc : 98B - 600Vdc : CSA C22.2 Nr. 4 [4 poles in series]

1500Vdc : IEC 60947-3  - 1000Vdc : 98B - 600Vdc : CSA C22.2 Nr. 4 [3 poles in series per circuit]

For ungrounded systems, see NEC 690.35 

(NEC2008, NEC2011, NFPA70).

Grounded systems :  in some installation standards, this 

configuration might not be allowed .

+

(-)

-

(+)

1

+

(-)

-

(+)

For each
circuit :

!

COMPULSORy

POlE CONNECTION IN SERIES

!

OBLIGATOIRE

CONFIGURATION RACCORDEMENT

OBLIGATORIO

!

CONExIóN DE lOS POlOS EN SERIES

1000Vdc : 98B, IEC 60947-3  -  600Vdc : CSA C22.2 Nr. 4 [2 poles in series per circuit]

Para mayor claridad, sólo se describe un tipo de conexión. Todos 

los polos son independientes y sin polarización así que la 

conexión de los polos en serie se puede realizar entre polos  que 

están  contiguos o no, en el mismo lado o en el lado opuesto del 

producto. Siempre de un mismo equipo. El número mínimo de polos 

a conectar en serie debe corresponder a las siguientes indica-

ciones para las características técnicas mencionadas. El radio de 

curvatura de los cables y las distancias entre las partas activas y 

pasivas respetar las normas de instalación NEC. Por ello, la 

dimensiones mínimas de la envolvente deberíanser aumentadas. 

Para la conexión serie entre  los polos / pletinas de puenteado no 

suministras por Socomec debenser verificados los efectos térmicos.

Para productos con multi-circuitos, las cifras     ,    ,     y     

representan la conexión de cada circuito.

2 o varios circuitos separados se pueden conectar juntos en el 

lado del inversor.

1 2 3

4

For comprehension reason, only one type of connection is shown. 

As all poles are independent and non polarized, the pole connec-

tions in series can be done between adjacent or non-adjacent 

poles and on the same or opposite side of the same switch layer. 

The minimum number of pole to be connected in series must be 

as shown below for the given technical characteristics. Wire ben-

ding space as well as spacings have to be according to NEC or 

relevant installation standard. For this, the enclosure dimension 

might have to be increased.

For bridging bar and serial connections not supplied by Socomec, 

thermal effect have to be checked.

For multi-circuit products, the signs                    represent wiring 

for each circuit.

2 or more separated circuits can also be connected together on 

the inverter side.

1 2 3 4

Pour une meilleure compréhension, seul un type de raccordement 

est décrit. Tous les pôles sont indépendants et non polarisés, le 

raccordement des pôles en série peut être réalisé entre pôles 

adjacents ou non, sur le même coté ou le coté opposé du même 

boitier (avant ou arrière). Le nombre minimum de pôles à raccor-

der en série doit correspondre aux indications ci-dessous pour 

les caractéristiques techniques mentionnées. Le rayon de courbure 

des câbles ainsi que les distances entre conducteurs/parois doivent 

être selon le NEC ou la norme d’installation. Pour cela, la dimension 

minimum du coffret pourrait être augmentée. Pour les connections 

série entre pôles/barres de pontages non fournies par Socomec, les 

impactes thermiques doivent être vérifiés.

Pour les produits multi-circuits, les chiffres                    indiquent 

le raccordement de chaque circuit.

2 circuits ou plus peuvent aussi être connectés ensemble du coté 

de l’onduleur.

1 2 3 4

+

(-)

+

(-)

-

(+)

-

(+)

+

(-)

+

(-)

-

(+)

-

(+)

+

(-)

+

(-)

-

(+)

-

(+)

+

(-)

+

(-)

+

(-)

+

(-)

1

+

(-)

2

+

(-)

+

(-)

+

(-)

1

+

(-)

2

3

4

1

+

(-)

-

(+)

+

(-)

-

(+)

2

+

(-)

-

(+)

+

(-)

-

(+)

+

(-)

-

(+)

+

(-)

-

(+)

1

1

2

3

2

1

2

4

1

+

(-)

+

(-)

2

+

(-)

+

(-)

3

+

(-)

+

(-)

1

+

(-)

+

(-)

2

+

(-)

+

(-)

3

+

(-)

+

(-)

4

+

(-)

+

(-)

1

5

+

(-)

2

6

3

7

4

8

+

(-)

1

4

2

5

3

6

+

(-)

+

(-)

1

2

+

(-)

+

(-)

+

(-)

+

(-)

3

4

1

2

+

(-)

+

(-)

+

(-)

+

(-)

+

(-)

-

(+)

+

(-)

-

(+)

2

1

+

(-)

+

(-)

+

(-)

-

(+)

2

1

+

(-)

-

(-)

+

(-)

+

(-)

+

(-)

-

(+)

-

(+)

+

(-)

1

2

+

(-)

+

(-)

+

(-)

+

(-)

+

(-)

+

(-)

Reviews: