![socomec COUNTIS M33 Manual Download Page 7](http://html1.mh-extra.com/html/socomec/countis-m33/countis-m33_manual_1311306007.webp)
- 3 -
Part 2 General Specifications
2.1 Specifications
Voltage
:
Rated Voltage (Un):3x230(400)V
Operational voltage: 80~120%
Current
:
Rated Current (Ib)
:
10A
Max Current (Imax)
:
100A
Over current withstand: 0.4% Ib~Imax
Over current withstand: 20 Imax for 0.5s
Operational frequency
:
Rated
:
50/60Hz
Range
:
45-65 Hz
Insulation capabilities
:
AC voltage withstand 4KV/1min
Impulse voltage withstand 6kV – 1.2µS waveform
Internal Power Consumption
:
≤ 2W.
Pulse Output 1
:
Configurable
Pulse Output 2
:
Fixed 400imp/kWh
Display
:
LCD with backlit
Max reading: 999999.99 kWh / kvarh
2.2 Accuracy
Voltage
:
0.5%
Current
:
0.5%
Frequency
:
0.2%
Power Factor
:
1%
Active Power
:
0.5%
Reactive Power
:
±1%