9. CONFIgUraTION
The device can be configured directly from the COUNTIS E13/E14 screen in programming mode or via the
communication link. The paragraphs below describe configuring using the screen.
9.1. Onscreen configuration
From the screen, go to programming mode to change your communication settings. How to browse through the
programming mode is described in the following stages:
Function
where
Buttons
Press
Switch menus
Every page except SETUP
menu
Double speed
(x2 < 0.5 sec)
Switch pages within a menu
Every page within a menu
Realtime
Go to SETUP menu
Menu page SETUP
> 3 sec
Change a value/digit
SETUP pages
realtime
Confirm a value/digit
SETUP pages
Double speed
(x2 < 0.5 sec)
Exit SETUP menu
SETUP Menu
> 3 sec
Start/stop the displayed partial meter
Partial meter menu
> 3 sec
Reset the displayed partial meter to zero
Partial meter menu
> 3 sec
Display test
Every page with the
exception of SETUP and
partial meters
> 10 sec
9 .1 .1 . View all of the menu "SETUP"
In the SETUP menu, press "
" for 3 seconds to put the device into programming mode.
Press "
" to go to the different screens:
>3s
Communication address
Communication speed
Communication parity
Communication stop bit
Reset partial energy to zero:
Ea+ partial (kWh) Tariff T1, T2
Ea+ partial (kWh)
Ea- partial (kWh) Tariff T1, T2
Ea- partial (kWh)
Eap partial (kVAh)
Er+ partial (kVarh)
Er- partial (kVarh)
Back to first screen of "SETUP" menu