background image

D

18.31

465

5.7

144,8

14.92

379

7.13

181

min. 2.75

min. 70

Max. 14

Max. 

355,6

Min. 13.3

Min. 

338

4.23

107,5

L

2.02

51,4

8.01

203,4

1.77

45

P

B

W

H

4x Ø 0.41

4x Ø 10.5

9.45

240

2.52

63,90

1.89

48,10

7.09

180

6.30

160

8.66

220

A

3.93

99,8

1.56

39,7

Dual Dimensions

in

/mm

SWITCH DIMENSIONS

MINIMUM ENCLOSURE SIZE

A

B

L

P

H

W

D

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

100-200A

2P

10.47

266,30

1.25

31,80

3.85

98,70

1.38

35

20

508

16

406

12

305

2P+N/ 3P

11.85

301,30

1.25

31,80

5.49

133,70

1.38

35

20

508

16

406

12

305

3P+N/ 4P

13.24

336,30

1.25

31,80

6.60

168,70

1.38

35

20

508

16

406

12

305

260-400A

2P

11.67

296,30

1.55

39,30

5

128,60

1.97

50

48

1220

24

610

12

305

2P+N/ 3P

13.63

346,30

1.55

39,30

7

178,60

1.97

50

48

1220

24

610

12

305

3P+N/ 4P

15.60

396,30

1.55

39,30

8.97

228,60

1.97

50

48

1220

24

610

12

305

Product dimensions

Switch & minimum enclosure size dimensions (4th pole represented with lugs installed.)

Controller dimensions

Switch top view

1B

Summary of Contents for ATyS FT

Page 1: ...s recommended to replace the complete product Installation standards must be respected Accessories Accessories are not included and must be ordered seperatly Terminal shrouds see step 6A Additional aux contacts ref 96990021 Digiware I O 10 ref 48290140 Transformer 480 240 VAC SPARTAN SP350MQMJ Controller 24 VDC aux power supply 6W minimum type SELV mandatory with I 0 10 Modules Power terminal lugs...

Page 2: ... 10 47 266 30 1 25 31 80 3 85 98 70 1 38 35 20 508 16 406 12 305 2P N 3P 11 85 301 30 1 25 31 80 5 49 133 70 1 38 35 20 508 16 406 12 305 3P N 4P 13 24 336 30 1 25 31 80 6 60 168 70 1 38 35 20 508 16 406 12 305 260 400A 2P 11 67 296 30 1 55 39 30 5 128 60 1 97 50 48 1220 24 610 12 305 2P N 3P 13 63 346 30 1 55 39 30 7 178 60 1 97 50 48 1220 24 610 12 305 3P N 4P 15 60 396 30 1 55 39 30 8 97 228 60...

Page 3: ...831 Contact us 1 6 250 KCMIL 275 31 1 5 16 70 8 8 5mm 1 25 4 100 200 A CMC LA 300R 39542020 2 1 6 300 KCMIL 275 31 1 5 16 70 8 8 5mm 1 12 28 4 39543020 3 39544020 4 260 400 A CMC LA 630R 39542040 2 1 4 600 KCMIL 550 62 1 1 2 310 35 8mm 1 79 45 7 39543040 3 39544040 4 260 400 A Ilsco D3096 Contact us 1 4 600 KCMIL 600 67 8 1 2 310 35 8mm 1 79 45 7 Power cable connections For 100A use 1 0 AWG For 20...

Page 4: ...ers not delivered with the product Fix FASTON connectors according to the table in step 2C Max 2 FASTON per pole Wires must not be in contact with active voltage points such as unused FASTON connections and lugs In order to do so any unused or loose cables must be tensed then fixed on a non conductive part of the transfer switch use cable tie fixation points as shown in the images below 1 Pass wir...

Page 5: ...4 4 5 3 lb in Sensing source 2 SOURCE 2 L1 L2 L3 N Voltage sensing inputs source 2 voltage supply L1 L2 Inputs 71 IN1 SWITCH IN POS1 Do not connect to any external power supply AWG 20 14 0 5 2 5mm 72 IN2 SWITCH IN POS 2 73 IN3 DOOR OPEN 74 IN4 programmable input 4 75 IN5 programmable input 5 76 IN6 programmable input 6 70 Common point for inputs Aux power supply 81 82 negative terminal for aux sup...

Page 6: ...n the configuration will go as follow SMART WIZARD CONFIG For advanced configuration go to parameters menu Language Source config Time date Switch Application Product Name Communication In STEP 5 8 of the wizard config make sure the network detected matches your network In STEP 6 8 make sure the switch technology parameter is set to ATyS FT If a fault is shown on the controller correct the associa...

Page 7: ...he LCD screen that may show distortion below 32 F 0 C Inspection of power contacts WARNING More than one live circuit Disconnect all sources of supply before servicing and or before using the manual operation Clip to maintain cover upright Slide cover to access service handle hole For manual operation operate handle 4 up from S2 to S1 down from S1 to S2 FAST OPERATION Recommendation carry out one ...

Page 8: ...and push back V Place the transparent plastic piece to cover the auxiliary conacts and lock in place in order to protect from direct contacts Use the correct protection according to your auxiliary contact circuit and your load Switch has 2 pre installed auxilliary contacts the kit below is for 2 additional contacts with protection against direct contact Ref 96990021 a b PH2 screwdriver Tightening ...

Reviews: