Technical manual
Sylax FM - CNPP
uksylaxfm_cnpp - Updated 12/01/2018
6
Overall dimensions
H1
H2
E
D1
D2
N holes ØR on ØS
ØT
flat P
Square CxC
4
H3
H4
ØU
H4
H3
ØU
4
N holes ØR on ØS
Square CxC
ØT
flat P
FM version
CNPP version
See on page 7
DN NPS
Iso top according to ISO 5211
Square drive outlet
N ØR ØS ØT ØU N° oC H3
flat P H4
32/40 1
1/2
4 6,5 50 65 36 F05 11* 19 11 12
50
2 4 6,5 50 65 36 F05 11* 19 11 12
65 2
1/2
4 6,5 50 65 36 F05 11* 19 11 12
80
3 4 6,5 50 65 36 F05 11* 19 11 12
100
FM 4 4 8,5 70 90 56 F07 14 19 14 12
100 CNPP 4 4 6,5 50 65 36 F05 11* 19 11 12
125 5 4 8,5 70 90 56 F07 14 19 14 12
150 6 4 8,5 70 90 56 F07 14 19 14 12
200 FM 8
4 10,5 102 125 71 F10 17 25 20 15,5
250 FM 10 4 10,5 102 125 71 F10 22 32 26 16
300 FM 12 4 12,5 125 150 87 F12 22 29 26 16
200 CNPP
8 4 8,5 70 90 56 F07 14 19 14 12
250 CNPP 10 4 10,5 102 125 71 F10 17** 24 20 14
300 CNPP 12 4 10,5 102 125 71 F10 22 29 22 14
* with conversion sleeve 14x11
** with conversion sleeve 17x22