Technical manual
Sylax FM - CNPP
uksylaxfm_cnpp - Updated 12/01/2018
12
Pressure
DIRECTIVE 2014/68/UE Equipments under pressure.
Products manufactured in conformity with the requirements of the directive, according to pressure, DN
and fluid (see on the precedent page )
.
PS : Maximum allowable pressure (in bar) according to Directive 2014/68/UE
PFA : Allowable operating pressure (in bar) for supply, distribution and disposal of water.
Torque values
Torques for water in Nm
EPDM
32/40
50
65
80
100
125
150
200
250
300
PS16
15
18
30
32
50
83
115
180
280
430
PS16 CNPP
15
15
20
26
45
53
66
123
295
346
One actuation minimum per month.
LINERS
DN mm Cat
.
MOUNTING
PFA
PS
L1 L2 G1
G2
16 bar EPDM (CNPP Approval),
EPDM (FM Approval)
32 to 300 4.3
Flanges
16
16
End of line
12
12