background image

4

2. Description

The UK designed EPF PRO is a dual function hazardous voltage and live phase
finder which will detect whether voltages greater than 50VAC are present in
order to protect operatives from dangerous live circuits, direct contact or
leakage situations at electrical cabinets,  street lighting columns and wooden,
concrete and metal poles carrying live overhead supplies.

Identification of live phase conductors

As the EPF PRO uses direct contact for measuring (using safest method known,
capacitive coupling). The identification of the live phase is more certain than
using non-contact voltage indicators or similar devices.

The EPF PRO is extremely safe to use as there is no need to operate touch pads
or any other direct contact method to operate the unit correctly.

  Meets international safety standard BS EN 61010-1:2010

  Voltage measurement range 50 – 600VAC

  Safe live phase detection

  Flashing red front section plus audible warning indicates greater than

50VAC is present

  Slow flashing blue LED with single beep monitors EPF PRO electronics

are working correctly

  EPF PRO is fully functional even if wearing full PPE

  Robust construction with IP54 water and dust ingress rating

  Probe tip conforms to HSE recommendations GS 38

3. Usage

3.1 Battery Installation and Status

The EPF PRO uses 2 x LR6 AA alkaline batteries - rotate the battery cover at the
base of the unit using a coin or similar, insert the batteries (negative terminal
first) and replace cover.  After inserting batteries and before use test the unit for
correct operation.

To check battery status, with nothing connected switch the EPF PRO on. If the
blue LED flashes and the front section illuminates, the electronics are working
correctly and the batteries are good .If the front section red LED flashes the
batteries need replacing.  Dispose of batteries as required by local regulations.

Summary of Contents for EPF PRO

Page 1: ...Instruction Manual Specification EPF PRO Hazardous Voltage and Phase Finder Issue2 02 16 SnS008v1...

Page 2: ...ion manual Construction is double insulated Product should be recycled as electronic waste Conforms to EU standards Measurement Category IV is applicable to test and measuring circuits connected at th...

Page 3: ...es if the instrument is connected to a live circuit 1 3 Limitations of Using the EPF PRO to Detect Hazardous Voltages The limitation of any single pole voltage testers is that a so called ghost voltag...

Page 4: ...010 Voltage measurement range 50 600VAC Safe live phase detection Flashing red front section plus audible warning indicates greater than 50VAC is present Slow flashing blue LED with single beep monito...

Page 5: ...single beep monitors EPF PRO electronics are working correctly Main on off switch Turn the unit on by pressing and briefly holding this button The blue LED above the finger guard flashes slowly and i...

Page 6: ...rasives or solvents There are no user serviceable parts Contact Socket and See for parts and technical assistance Socket and See Century Road High Carr Business Park Newcastle Staffordshire UK Tel 44...

Page 7: ...ting IP54 Operating Conditions 18 to 55 C at 85 RH Overvoltage Category CAT IV 300V Batteries 2 x LR6 AA alkaline batteries not included Battery Life It is recommended to replace the batteries every t...

Page 8: ...Ordering Information Item Supplier Code Socket and See EPF PRO SOC EPFPRO Socket and See EPF PRO case SOC TECCEPF...

Reviews: