Soca AP--60 User Manual Download Page 8

(3). Use attac hed d isc s

E TM.EXE

to set TCP/ IP Converter s

First IP 

】 

'

'

 

Run ETM.EX E to list LAN s TC P/IP Converte r. Cl ose all existing fir ewa ll software 
in or der to rec eive TCP/IP Converter s response pa ckages. 

'

 

Check the IP fr om t he list to make sure it has been changed to 192 .168.10.250 or pre ss 

to refresh the page. 

【  5】

 

Please ke ep th e only

TCP/IP Converte r to set IP Address . 

 

one 

Se t TCP/IP Converte r's IP as s ame as th e PC's network segment in o rder to use browse r 
to enter to T CP/ IP Converters setti ng page. 

6

 

(4). Click

】->【

】->【

 

Config

IP Address

ente r 192.1 68.10.250

Summary of Contents for AP--60

Page 1: ...SOCA TECHNOLOGY CO LTD 2005 AUGUST AP 60 RS232 485 to TCP IP USER MANUAL R ...

Page 2: ...Front Panel Connector instructions 3 Specifications 4 Network Bus type 5 TCP IP converter setting 5 1 Network specifications 5 2 Before setting 5 3 Setting TCP IP Converter 6 Example 1 7 Trouble shooting 1 1 1 2 3 3 5 7 9 12 ...

Page 3: ...nchronous half duplex 2 wire RS 485 network 2 Front Panel Connector instructions VCC GND 485 DT 485 DT 232 SGO 232 TDX 232 RXD TCP IP RJ 45 485 232 3 Specifications DC 12V 50mA 1 RS 232 DB 9 2 RS 485 4terminal Block 9600 bsp Poly carbonate Max 1 2Km 110 70 25 mm 180g Power Current Connecor Baud rate Case Valid Distance Dimension Weight 1 ...

Page 4: ... is about 1 2K m try 110 first The above value or parameters are for user s reference Please increase or decrease the value in accordance to the specific length used Ω Ω Ω IBM相容電腦 P O WER T X D R X D A P 30A RS 2 3 2TO RS 485 CONVE RTER RS 232 RS 485 Valid Distance 1200Meters Can be expanded to 255 sets Max Device 1 Device N Device N 1 對絞線 鋁箔層 隔離網 外皮 AWG24 雙隔離網線 對絞線 鋁箔層 隔離網 外皮 AWG24 雙隔離網線 AP 30 RS...

Page 5: ...etting The network specification of TCP IP converter and the PC is as below 1 Standard setting with Hub 2 Use crossover network line to connect with PC 3 Other network specification Broadcasted packages sending by PC have to be able to receive by each node Attention All network settings have to be constructed by appointed personnel in order to avoid any failure occurred 3 ...

Page 6: ...wn 8 brown Connector B 1 braided white and green 2 green 3 braided white and orange 4 blue 5 braided white and blue 6 orange 7 braided white and brown 8 brown Please note that when connecting TCP IP and the reader 485 has to be connected as the following connect R and T together and then connect both to DATA connect R and T together and then connect both to DATA Please note that when connecting AP...

Page 7: ...st and setting TCP IP as the same network segment The steps are as below 1 In MS DOS mode Start Run Enter command Enter 2 Enter ipconfig Enter Example If the PC s IP is 192 168 10 20 user will only need to set TCP IP Converter as 192 168 10 x to avoid any crash with other IP 5 ...

Page 8: ...nverter s response packages Check the IP from the list to make sure it has been changed to 192 168 10 250 or press to refresh the page 5 F Please keep the only TCP IP Converter to set IP Address one Set TCP IP Converter s IP as same as the PC s network segment in order to use browser to enter to TCP IP Converters setting page 6 4 Click Config IP Address enter 192 168 10 250 ...

Page 9: ...e browser to enter to TCP IP Converter s setting page when the IP is set 1 Enter and the following page will appear as below No default password needed to login http 192 168 10 250 2 The following setting page will appear as below 7 ...

Page 10: ...CP Server Select and set as TCP server Socket port value ranges from 1024 65535 101 UDP Set this value as permanent as user will not need this function ST 680 sets as 9600 N 8 2 ST 3000 sets as 9600 N 8 1 ST 6000 sets as 9600 N 8 1 SF 1000 sets as 9600 N 8 1 SF 1000T sets as 9600 N 8 1 ST 500A sets as 9600 N 8 1 Select RS 232 if the external reader is using RS 232 communication mode Select RS 485 ...

Page 11: ...T 680 are not at the same network segment 1 Setting TCP IP Converter at 203 70 1 x Follow the steps at 1 2 to set TCP IP Converter IP as 203 70 1 12 which is the same network segment as PC 2 Use browser to enter to TCP IP Converter setting page Set it as 203 70 2 12 ST 680 uses RS 485 to connect to TCP IP Converter The setting is as below 9 ...

Page 12: ... when TCP IP Converters IP and computer are at the same network segment Browser will Execute ETM EXE to browse if TCP IP Converters IP has been changed 4 Add new to connect communication interface TCP IP Converter value of be the same as Setting When there is no response from WAN network increase the value of TIMEOUT to increase the software s response time Receive Port must Socket port of serial ...

Page 13: ...ST 680 s communication interface to this TCP IP converter in Reader Setting 6 All communication from both software and ST 680 are through network to TCP IP Converter and vice versa when all settings are set 11 ...

Page 14: ... IP as a fixed IP in order to detect AP 60 easily AP 60 also supports DHCP and user needs to set the IP as a fixed or reserved IP 4 Setting real IP a Use ETM program to set real IP for AP 60 under the same segment and set both Gateway and Submask correctly 5 How to use floating real IP ADSL The IP needs to accommodate with IP Router and Dynamic DNS a Apply free dynamic DNS from http www dyndns org...

Page 15: ...ol or time attendance software is set correctly Please check the communication interface which included IP Port Communication TCP or UDP f Check if software s reader number and communication interface are selected correctly 13 ...