Standard wiring of R J45 connector:
From left to right: (1) braided white and orange, (2) orange, (3) braided w hite and green,
(4) blue, (5) braided white and blue, (6) green, (7) braided white and
brown, (8) brown .
Crossover wiring of RJ45 connector :
Connector A: (1) braided white and orange, (2) orange, (3) braided white and green, (4) blue,
(5) braided white and b lue, (6) green, (7) braided white and brown, (8) brown.
Connector B: (1) braided white and green, (2) green, (3) braided white and orange, (4) blue,
(5) braided white and b lue, (6) orange, (7) braided white and brown, (8) brown.
※
Please note that when connecting TCP/IP and the reader; 485 has to be connected as the
following:
connect R and T together and then connect both to DATA;connect R+ and T+ together
and then connect both to DATA+.
※
Please note that when connecting AP60 and the reader, 485 has to be connected as follows:
sw itch to RS485, and switch the reader to RS485 as well, and then connect DT+ and DT
w ith DATA+ and DATA together.