SNT ACL2 120 Installation, Operation And Maintenance Manual Download Page 9

4.1.2

 

Standard operating conditions 

The  actuator  must  be  used  in  an  environment  whose  conditions  comply  with  the  provisions  of  S

NT

.  The

works  necessary  for  obtaining  and  maintaining  that  conditions  are  in  charge  of  the  owner  and,    where 
applicable, are in charge of the end user. 

The actuator must be installed and used indoor only, in dry area with environmental conditions as specified 
below: 

Temperature range

+0°C ÷ +40°C 

Relative atmospheric humidity

5% ÷ 85% 

No build up of condensation
THE USE OF THE ACTUATOR IN DIFFERENT CONDITIONS THAN JUST DESCRIBED MUST BE PREVIOUSLY
DECLARED AND AGREED WITH S

NT

, SINCE A SPECIAL EQUIPMENT OF THE PRODUCT MUST

 

BE

PROVIDED.

4.1.3

 

Thermal limit 

The actuator duty cycle permissible Fi [%] is the maximum working time expressed in percentage that the 
actuator  can  perform  during  the  reference  time  period  of  10  minutes,  under  rated  load  stated  in  the 
catalogue at ambient temperature 25°C, without risk of internal parts overheating. 

𝑭

𝒊

[%] =

𝑀𝑎𝑥 𝑤𝑜𝑟𝑘𝑖𝑛𝑔 𝑡𝑖𝑚𝑒 𝑜𝑣𝑒𝑟 10 𝑚𝑖𝑛

10 𝑚𝑖𝑛

× 100

 

Linear drive 

Fi [%] 

Acme screw (A

CL2

 series)

30 

Ball screw (

ACL2 B

 series)

100 

For the proper operation of acme screw linear actuators (A

C

L

2

 series) do never exceed the

permissible duty cycle limit. 

4.2

 

Personnel requirements / Qualifications 

This  manual  must  be  made  available  to  the  personnel  in  charge  of  installation,  start  up  and  use  of  the 
actuator. It is the responsibility of the machine builder:  

use personnel with the necessary qualifications for the installation and commissioning of the
actuator;

periodically check the qualification of the assigned personnel;

check that the personnel in charge are aware of the contents of this manual.

5

 

STORAGE 

Do not store outside.

Storage should be dry and dust-free.

Keep away from any aggressive media.

Protect from UV radiation.

Avoid mechanical vibrations.

Storage temperature:  0 to +50 °C.

Relative atmospheric humidity: max. 95% (no build up of condensation).

To store longer than 6 months, take care of moving the input shafts to prevent damages to
sealings.

Also check that all unpainted steel parts are adequately protected (oiled and /or greased) to
prevent oxidation.

Summary of Contents for ACL2 120

Page 1: ...ON AND MAINTENANCEnance NO 01 210003 LINEAR ACTUATORS ACME SCREW ACL2 120 ACL2 125 ACL2 128 ACL2 130 ACL2 140 BALL SCREW ACL2 120B ACL2 125B ACL2 128B ACL2 130B ACL2 140B ENGLISH Ed 08 2021 02 20 25 2...

Page 2: ...elieve SNT from any liability for damage caused to persons and or property SNT does not assume direct or indirect responsibility for an improper use of the actuator not respecting the performances of...

Page 3: ...CTION 8 4 1 Intended use 8 4 1 1 Use restrictions 8 4 1 2 Standard operating conditions 9 4 1 3 Thermal limit 9 4 2 Personnel requirements Qualifications 9 5 STORAGE 9 6 INSTALLATION 10 6 1 Safety war...

Page 4: ...4 8 LUBRICATION 20 9 MAINTENANCE 20 9 1 Maintenance of ACL2 ACL2 B 20 25 28 actuators 20 9 2 Maintenance of ACL2 ACL2 B 30 40 actuators 20 9 2 1 Linear drive lubrication 21...

Page 5: ...he product For all the technical characteristics of the product performance features dimensions refer to the technical catalog Main actuator components 1 Push rod 2 External tube 3 Gearbox housing 4 R...

Page 6: ...t 1 Product code is an alphanumeric code stating the type of the linear actuator 2 3 Serial number is the identification number of the actuator which identifies the exact design of the product even af...

Page 7: ...inear actuator the push rod must be in retracted position Lift the actuator from the housing and outer tube supporting the motor during transport DO NOT lift the actuator from the push rod and or the...

Page 8: ...xial applied load They must be subjected to the loading and speed conditions specified in the catalog Modification of parts of the actuator or replacement of components with different and non original...

Page 9: ...internal parts overheating 10 10 100 Linear drive Fi Acme screw ACL2 series 30 Ball screw ACL2 B series 100 For the proper operation of acme screw linear actuators ACL2 series do never exceed the perm...

Page 10: ...OF THE PRODUCT BEFORE TO PROCEED TO THE ELECTRIC CONNECTION MAKE SURE THE SUPPLY VOLTAGE IS TURNED OFF BEFORE TO TURN ON THE MOTOR MAKE SURE THE ELECTRIC CONNECTIONS ARE TIGHTENED AND STABLE CHECK PO...

Page 11: ...D ACTUATOR stop position Ring 2 activates FC 2 switch and fixes the required EXTENDED ACTUATOR stop position To setup the stop positions simply release the grub screw on the ring move it on the requir...

Page 12: ...ogue or to the check sheet supplied with the actuator When using more contact reeds for intermediate positions it shall be considered that the same reed switch can give the signal in 2 different posit...

Page 13: ...ES Contact NC NO Switching output Reed Supply voltage 5 120 V AC DC 1 5 230 V AC DC 2 Voltage drop 0 35 V Continous current 100 mA AC Switching capacity 6 W Protection class II Enclosure rating IP 65...

Page 14: ...ing IP 55 The rotary encoder ENC 4 must be connected to the electric control circuit as shown in the following WIRING DIAGRAM 6 5 Rotary encoder GI 2X THE ROTARY ENCODER GI 2X IS AVAILABLE ONLY FOR AT...

Page 15: ...s device is a torque limiter on the worm wheel The torque limiter clutch is preloaded during assembly The preload is fixed and related to the ratio and the performances of each actuator as stated on t...

Page 16: ...16 6 8 Electric motor wiring PLEASE REFER TO INSTALLATION INSTRUCTIONS OF THE ELECTRIC MOTOR SELECTED FOR THE ACTUATOR...

Page 17: ...PREVENT DAMAGE TO PERSONS OR PROPERTY Check that all plant fixing elements are well machined and cleaned and that they fit the dimensions of the actuators fixing elements they have to be fixed to If t...

Page 18: ...E ACTUATOR 6 10Installation of rod end fitting elements To install a mounting element on the rod end threaded bore BA use a wrench flat on the rod end to counterhold the locking torque In case of actu...

Page 19: ...e actuator then run the actuator GRADUALLY from the control unit in order to reach the plant to its more distant extreme position Check continuously the current actuator length during the motion Repea...

Page 20: ...OULD BE USED PLEASE CONTACT SERVOMECH BEFORE PROCEED IN CASE OF CUSTOM PRODUCT EXECUTION THE LUBRICANTS COULD BE DIFFERENT FROM THE STANDARD ABOVE TO KNOW THE TYPE OF LUBRICANT PLEASE REFER TO THE PRO...

Page 21: ...rease nipple type DIN71412 M6 Figure 9 2 Linear drive relubrication of ACL2 ACL2 B 30 40 Apply the grease quantity indicated in Tab 9 1 with several partial quantities Travel over the entire stroke be...

Page 22: ...SNT 2 rue Marcel Dassault Z I Croix Saint Nicolas 94510 LA QUEUE EN BRIE Tel 01 45 93 05 25 Fax 01 45 94 79 95 Email contact snt tm fr www snt tm fr...