background image

The Big Bear has some simple instructions that must be followed carefully in order to create rich 
foam, ensure the safety of the operators/participants, and to protect the equipment from damage. 
PLEASE FOLLOW THESE INSTRUCTIONS CAREFULLY.

The Big Bear uses a sump pump and a premixed solution to ensure that the solution flow rate is 
ideal in the creation of foam. The two electrically operated pieces of equipment in the Big Bear are 
the Sump Pump (110V or 220V) and the Blower-fan (110V or 220V), and are controlled by a GFI.

1) Prepare the area you intend to fill with foam. Always prepare your foaming area; making sure it 
is a surface free of obstructions such as steps, standing water, cables, ledges, electronic equipment, 
rocks, toys and sharp objects before generating foam. Note that if the area surface is linoleum, it will 
be much more slippery than an outdoor carpet, concrete or lawn. Always warn participants that the 
foam can make the floor slippery, which is part of the fun.

2) Locate the Big Bear exactly in the middle of the area you intend to fill with foam. Place Big Bear 
in the desired direction. Make sure the Big Bear is resting on a surface that is level and dry. It should 

never be located within 10 ft of a 
swimming pool, steps or ledge without 
a guardrail.

3) Prepare the foam solution in a 
plastic container (per the “Solution 
Mixture” section) and locate it within 
15 ft of the Big Bear. The container 
should always be plastic.  Lower the 
Sump Pump into the container. Plug in 
the Sump Pump Cord to the electric 
connector on the Big Bear’s electronic 
GFI power supply. 

The Big Bear 

should never be plugged into the 
electrical outlet when lowering 
or raising the Sump Pump from 
the solution container.

  The Sump 

Pump should never be run with less 
than an 1/8” of solution in the solution 
container or you will damage the 
pump.

4) After clearing people away from 
the nozzle end of the Big Bear, plug 
the electric cord into the 110V or 
220V outlet. Press down on the switch 
marked “ON” to turn on the Big Bear.  
In less than 10 seconds, foam should 
flow out of the Big Bear nozzle.  If 
foam is not created after 1 minute, turn 
off and unplug the Big Bear. Review 
the Q/A Problems section in this 

4

General Operating Instructions

Operating Instructions:

O

pe

ra

ti

ng

 In

st

ru

ct

io

ns

Summary of Contents for Big Bear

Page 1: ...tions such as steps standing water cables ledges electronic equipment rocks toys and sharp objects before generating foam Never place the pump in water or remove the pump from the water while the Big Bear is plugged into an electronic socket Always use a plastic container to hold solution Do not run the Big Bear while the solution container has a water or solution level lower than 1 8 Never use wa...

Page 2: ...rvice GFI Protection Voltage 110 60 Hz or 220 60 Hz Fuse 20 Amps Size 22 5 Wide 22 Long and 22 Tall Weight 50 lbs Materials Predominately Plastic Foam GenerationRate 500 cubic square feet per minute approximate Cable Length 20 feet Hose Length 10 feet 2 Big Bear Features and Specifications Features Features and Specifications Specifications Solution Inlet 5 Feet Tripod Hanging Points GFI Power Sup...

Page 3: ...on will automatically void the lifetime warrranty Always mix and store the Solutions in a plastic container FG HDF Solution The ratio for this foam solution is 50 units of water to 1 unit of solution See the chart below for some examples of common water solution ratios for the FG HDF Solution only Minimum Container Size Water FG HDF Solution Gallons Quarts Ounces 12 gallons 10 gallons 2 8 26 26 ga...

Page 4: ... you intend to fill with foam Place Big Bear in the desired direction Make sure the Big Bear is resting on a surface that is level and dry It should never be located within 10 ft of a swimming pool steps or ledge without a guardrail 3 Prepare the foam solution in a plastic container per the Solution Mixture section and locate it within 15 ft of the Big Bear The container should always be plastic L...

Page 5: ...hose may affect foam output Electrical Wire Damage Snow Masters will repair all wire damage per the lifetime warranty General Repair The Snow Masters Big Bear has a lifetime warranty and should never require you to remove the electrical panel or fan guard extreme danger Please contact Snow Masters if you have questions on its operation or warranty WARRANTY WILL BE AUTOMATICALLY VOIDED IF REPAIRS A...

Page 6: ...hnical Service c Adjust the hand valve below the Big Bear to a number of positions to see if it helps generate a dryer or wetter foam Create another batch of solution and double check that you match one of the solution mixtures noted above for the correct solution type Retest the Big Bear with the new solution batch If it still does not generate foam call Foam Masters Technical Service d Is the mi...

Page 7: ......

Page 8: ...negligence automatically voids our warranty Running any liquids materials other than water and the Snow Masters solutions through the pump Big Bear automatically voids our warranty Snow Masters is not responsible for loss of income labor or business as a result of a Big Bear malfunction Snow Masters is not responsible for physical damage scratching or hose damage after shipping from Snow Master s ...

Page 9: ...The Ultimate Foam Generator The Big Bear Foam Machine www SnowMasters com 2010 SnowMasters Inc ...

Reviews: