background image

m

WARNING! 

Water that has flown through backflow 

preventers is considered to be non-potable.

m

WARNING! 

During cleaning, maintenance or when 

replacing parts, the machine must be disconnected from its 
power source by removing the plug from the socket outlet. 

m

WARNING! 

High pressure hoses, fittings, and couplings 

are important for the safe operation of the appliance. Use 
only hoses, fittings, and couplings recommended by the 
manufacturer. 

• 

Check for damaged parts – 

Do not use the appliance if the 

supply cord or other important parts of the appliance are 
damaged (e.g. safety devices, high pressure hoses, trigger 
gun).

m

WARNING!

 If an extension cord is used, the plug and 

socket must be of watertight construction.

m

WARNING! 

Inadequate extension cords can be 

dangerous.

• This high pressure washer must not be used at 

temperatures below 32ºF (0°C).

m

WARNING! 

Power cords on drums should always be 

completely unwound to prevent the cord from overheating.

• Power cord connections should be kept dry and off the 

ground.

• Comply with the below requirements for length and cord 

specs (Table 1):

• If the power cord is damaged, it must be replaced by the 

manufacturer or his service agent or similarly qualified 
person in order to avoid a hazard.

• Keep the machine on a stable, flat surface during operation, 

handling, transportation, and storage. Sudden overturn of 
the machine can cause bodily injury.

• In the event of an accident or breakdown, switch off the 

machine immediately. (If contact with detergent occurs, 
rinse with an abundance of clean water.)

Electrical Safety

ATTENTION: 

If there are problems with the electrical 

MAINS, short voltage drops may appear when starting the 
equipment. This can, in turn, influence other equipment (e.g. 
cause a lamp to blink). If the MAINS-IMPEDANCE Zmax < 
0.335 OHM, such disturbances are not expected. (In case 
of assistance, contact your local supply authority for further 
information.)

m

WARNING!

 

Electrical Shock Hazard

Before starting up your machine, please check it carefully for 
any defects. If you find any, do not start up your machine and 
contact your distributor.

The following should be observed when connecting the high 
pressure washer to the electric installation:

• The electric supply connection should be performed by a 

qualified person.

• The electric supply to this appliance should include either 

a residual current device that will interrupt the supply if the 
leakage current to the earth exceeds 30 mA for 30 ms or a 
device that will interrupt the earth circuit (GFCI).

IMPORTANT: 

Only use water without any impurities. 

If there is a risk of running sand into the inlet water (i.e. from 
your own well), an additional filter should be installed.

Safety devices

The unloader valve can reduce pressure if it exceeds preset 
values. The spray gun features a locking device. When the lock 
is activated, the spray gun cannot be operated.

• 

Thermal sensor –

 A thermal sensor protects the motor 

against overloading. The machine will restart after a few 
minutes when the thermal sensor has cooled.

• 

Double insulation –

 In a double-insulated product, two 

systems of insulation are provided instead of grounding.  
No grounding means are provided on a double-insulated 
product, nor should a means for grounding be added to  
the product. Servicing a double-insulated product requires 
extreme care and knowledge of the system, and should be 
performed only by a qualified service person. Replacement 
parts for a double-insulated product must be identical to the 
parts they replace. A double-insulated product is marked 
with the words “DOUBLE INSULATION” or “DOUBLE 
INSULATED”. The symbol “   ” may also be marked on the 
product.

• 

Ground Fault Circuit Interrupter (GFCI) – 

This pressure 

washer is provided with a ground-fault circuit-interrupter 
(GFCI) built into the plug of the power-supply cord. This 
device provides additional protection from the risk of 
electric shock. Should replacement of the plug or cord 
become necessary, use only identical replacement parts 
that include GFCI protection.

Table 1

25 

 

 

 

 

18

18 

16 

50 

 

 

 

 

16

16 

16 

100 

 

 

 

 

16

14 

 

150 

 

 

 

 

14

12 

Volts

120V 

 

 

 

 

0 – 6

6 – 10 

10 – 12 

Total length of cord in feet

AWG

Not Recommended

Ampere Rating 

More than  

Not more than

2

Summary of Contents for Pressure Joe SPX3000RM

Page 1: ...are doing Use common sense Do not operate the pressure washer when you are tired or under the influence of alcohol or drugs Do not overreach Keep proper footing and balance at all times Avoid uninten...

Page 2: ...carefully for any defects If you find any do not start up your machine and contact your distributor The following should be observed when connecting the high pressure washer to the electric installat...

Page 3: ...of an assembly with a pump which is encased in a shock absorbing housing To provide the operator with an optimal working position the machine is equipped with a spray wand and a non slip handle grip...

Page 4: ...in center of trigger Pull up and snap in place See Fig 12 pg 7 2 Trigger 3 Handle 4 High pressure hose connection 5 Trigger gun 6 Spray wand 7 Water inlet garden hose connection 8 Spray wand protector...

Page 5: ...shipping If you find damaged or missing parts DO NOT return to the store Please call 1 866 766 9563 NOTE Do not discard the shipping carton and packaging material until you are ready to use your new...

Page 6: ...the slot located at the bottom left side of the unit and secure it in place with small screw Figs 8 9 8 To assemble the hose holder slide the holder into position Figs 10 11 and secure it to the unit...

Page 7: ...empt to mend a damaged hose 12 Connect the garden hose adaptor female coupler to the water inlet of the pressure washer then thread your garden hose male end into the garden hose adaptor Fig 16 The ga...

Page 8: ...ration mIMPORTANT This pressure washer is equipped with a micro switch sensitive to water flow This Total Stop System TSS senses water flow in the pump When the trigger is released water stops flowing...

Page 9: ...the safety lock until it clicks into the slot Fig 22 Snap the desired nozzle onto the quick connect collar until it clicks into place and is secured properly Fig 23 To disconnect a nozzle from the sp...

Page 10: ...ve the detergent suction tube from the detergent bottle and insert it into 5 L 1 gallon of fresh water Siphon water at low pressure for one minute so that all the detergent is flushed through the syst...

Page 11: ...l injury due to discharge of high pressure water Taking a break If you are taking a break of five minutes or more between cleaning tasks Engage the gun safety lock Turn the switch to the OFF 0 positio...

Page 12: ...dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated t...

Page 13: ...Clean the nozzle Change to an installation higher than the amp consumption of the machine You may try without the extension cord Allow machine to run with open trigger until regular working pressure...

Page 14: ...warranty Parts used that are not genuine Snow Joe parts are not covered by this warranty Damages resulting from misuse alteration improper assembly improper adjustment neglect or accident which requi...

Reviews: