Attenuation

The IQOTX33/34/35/36 modules have 1550nm transmission lasers, which have 
a higher optical power output than the 1310nm variety present on the IQOTX30/
31/32 modules. For link distances less than 15Km, this power is suffiecient to 
saturate receivers. As a precaution, all units with 1550nm transmission lasers are 
fitted with a 5dBm attenuator. For distances greater than 15Km, it may be 
desirable to use the extra optical power, in which case the attenuator can be 
removed.

To remove the attenuator:

1. Remove the card from the IQ enclosure.

2. Press down on the blue latch that holds the optical fiber connector in place 

and withdraw the opitcal fiber.

3. Press down on the blue latch that holds the attenuator in place and remove 

withdraw the attenuator from the SFP module.

4. Push the optical fiber connector directly into the SFP module. It will click 

when it is in place.

5. Refit the card into the IQ enclosure.

Take care not to touch the exposed glass tip of the optical fiber. 
If this does happen, clean the exposed tip with an isopropyl 
alcohol wipe.

Optical Fiber Cables

Attenuator

SFP Module

Note: 

Summary of Contents for IQOTX30

Page 1: ...Southleigh Park House Eastleigh Road Havant Hants PO9 2PE United Kingdom For General Enquiry s contact Tel 44 0 2392 489000 Fax 44 0 23 9245 1411 For Technical assistance contact Tel 44 0 2392 489058...

Page 2: ...l Profile 5 Warnings 7 Notes 7 Connections 8 IQOTX30 34 36 Connections 8 IQOTX31 33 Connections 8 IQOTX32 35 Connections 9 Card Edge Controls 10 IQOTX30 34 36 10 IQOTX31 33 10 IQOTX32 35 10 Attenuatio...

Page 3: ...puts Suitable for applications where 3G HD SDI signals need to be transported over long distances within a facility or between sites optical links remove the distance constraints of copper cabling at...

Page 4: ...2 1 SDI IN IQOTX31 33 Rear Panel View TX OUT 1 2 SDI OUT 1 IQOTX31 33 1A 2 1 SDI IN 4 3 IQOTX32 35 Rear Panel View TX OUT 1 SDI OUT 1 IQOTX32 33 1A 2 1 SDI IN 4 3 These modules can only be fitted into...

Page 5: ...er optic transmitter for 3G HD SD SDI 1 x 3G HD SD SDI input 4 x 3G HD SD SDI outputs 2 x optical output 1310nm 1310nm IQOTX31 3G Upgrade for IQOTX31 to operate with 3Gbps signals IQOTX32 IQOTX3257 1A...

Page 6: ...itter for 3G HD SD SDI 2 x 3G HD SD SDI inputs 1x2 1x1 3G HD SD SDI outputs 1 x optical output per channel 1550nm 1550nm IQOTX34 3G Upgrade for IQOTX34 to operate with 3Gbps signals IQOTX35 IQOTX3533...

Page 7: ...D SDI 1 485 Gbit s HD SDI or 270 Mbit s SD SDI asynchronous operation available at other frequencies Connector Format SC PC singlemode panel uniter Outputs One per channel Conforms to SMPTE 297 2006 E...

Page 8: ...wer OK Rx n Power High Rx n Power Low Tx n Bias OK Tx n Bias High Tx n Bias Low Where n is the Channel number 1or 2 Indicators Power OK Green CPU OK Green flashing Input 1 2 OK Bypass Green Bypass Ora...

Page 9: ...ould not be handled unless thier source can positively be identified as not exceeding Class 1 limits Notes Note Optical uniters have shutters to prevent the ingress of dust These shutters should only...

Page 10: ...via BNC 75 ohm panel jack connectors There are two ouputs on Channel 1 and a single output on Channel 2 IQOTX31 33 Connections Input SDI input to the module is via a single BNC 75 ohm panel jack conn...

Page 11: ...75 ohm panel jack connector Optical Output Optical output from the unit is via a single SC PC singlemode panel uniter IQOTX32 1310nm IQOTX35 1550nm Electrical Outputs SDI output from the module is vi...

Page 12: ...llgroup com IQOTX30 31 32 33 34 35 36 Page 10 Card Edge Controls IQOTX30 OK WARNING ERROR POWER OK CPU OK OK WARNING ERROR CH1 CH2 34 36 IQOTX31 OK WARNING ERROR POWER OK CPU OK 33 IQOTX32 OK WARNING...

Page 13: ...extra optical power in which case the attenuator can be removed To remove the attenuator 1 Remove the card from the IQ enclosure 2 Press down on the blue latch that holds the optical fiber connector i...

Page 14: ...Status Information about the status of the unit is displayed in the Unit Status section on each RollCall Control Panel screen The first two lines of the Unit Status display the input status detected...

Page 15: ...lected the output will be passed through SD DVB ASI 270 Mb When selected the unit will reclock only SD DVB ASI 270 Mb signals When selected the On Input Loss controls are greyed out and are inactive I...

Page 16: ...ed to Input 2 and Output 2 Fiber Optic Tx 1 Tx 2 The Fiber Optic Tx 1 and Fiber Optic Tx 2 areas display information about fiber optic transmission and provide options to disable the laser The informa...

Page 17: ...the Save Memory Name field type the new memory name and then cli click S To return the memory to its default value click the preset button P Use the Recall Memory function to recall the settings save...

Page 18: ...Version 1 Issue 2 www snellgroup com IQOTX30 31 32 33 34 35 36 Page 16 Logging Information about several parameters can be made available to a logging device that is connected to the RollCall network...

Page 19: ...gging field Log Value Displays the current log value RollCall Log Fields Log Field Log Value SN Serial number OS_VERSION Operating system version BUILD_NUMBER Software build number HARDWARE_VERSION Ha...

Page 20: ...e 2 www snellgroup com IQOTX30 31 32 33 34 35 36 Page 18 OUTPUT_N_LASER_BIAS Laser Bias in mA OUTPUT_N_TX_POWER_STATE OK WARN FAIL OUTPUT_N_TX_POWER Tx power measurement OUTPUT_N_WAVELENGTH Output wav...

Page 21: ...000 in the example is the network segment code number The second set 10 in the example identifies the enclosure mainframe unit The third set 01 in the example identifies the slot number in the unit Th...

Page 22: ...Viewing RollTrack Information RollTrack Sending and RollTrack Status display information about the status of RollTracks RollTrack Sending displays the information when the unit is actively sending a...

Page 23: ...s displays the unit s serial number Build This displays the factory build number This number identifies all parameters of the unit KOS This displays the operating system version number PCB This displa...

Page 24: ...X30 31 32 33 34 35 36 Page 22 Input 1 Name and Input 2 Name These are the input names displayed in logging To change the name of Input 1 or Input 2 type the name in the text field and click S To retur...

Page 25: ...f the unit Control Window The Control window displays all selection menus and sub menus The main or top level menu allows various sub menus to be selected by pressing the button adjacent to the requir...

Page 26: ...Version 1 Issue 2 www snellgroup com IQOTX30 31 32 33 34 35 36 Page 24...

Page 27: ...ersion 1 Issue 2 www snellgroup com IQOTX30 31 32 33 34 35 36 25 Manual Revision Record Date Version Issue Change Comments 12 05 09 1 1 First Issue 11 05 10 1 2 Added IQOTX33 34 35 36 modules New Issu...

Reviews: