IQAES00/01/10/11
N33
IQAES00OPS 27/07/06
www.snellwilcox.com
Version 1 Issue 1
N33.13
Logging
Information about various parameters can be
made available to a logging device that is attached
to the RollCall™ network by checking the
appropriate box.
The status is shown to the right of the item.
Any of the items may be selected from the list.
ROLLCALL LOG FIELDS
Log Field
Log Value
Description
INPUT_1_TYPE =
AES
Type of signal the module processes
INPUT_1_IDENT =
AESIN1
Input rear label
INPUT_1_AUDIO_CS_MO
Number
WARN:NoInput
Display’s Channel Status information (Byte 1 bits 0-3)
INPUT_1_AUDIO_TYPE
PCM
Non-PCM
WARN:NoInput
Detects what type of AES signal present
INPUT_1_AUDIO_RATE
WARN:NoInput
WARN:Unknown
32kHz
44.1kHz
48kHz
96kHz
Sample rate detection
INPUT_1_STATE =
OK
FAIL:Lost
The presence or lack of input
INPUT_2_TYPE =
WARN:NoInput
PCM
Non-PCM
Type of signal the module processes
INPUT_2_IDENT =
AESIN2
Input rear label
INPUT_2_AUDIO_CS_MO
Number
WARN:NoInput
Display’s Channel Status information (Byte 1 bits 0-3)
INPUT_2_AUDIO_TYPE
PCM
Non-PCM
WARN:NoInput
Detects what type of AES signal present
INPUT_2_AUDIO_RATE
WARN:NoInput
WARN:Unknown
32kHz
44.1kHz
48kHz
96kHz
Sample rate detection
INPUT_2_STATE =
OK
FAIL:Lost
The presence or lack of input