SHDSDA2
OPERATION
SHDSDA2
Version 1 Issue 3
030402
5
Technical Profile
INPUT (Channel 1 and 2)
Electrical
1.485GBit/s HD-SDI
Connector Format
BNC 75ohm panel jack
Input Cable Length
100m
Peak-to-peak
signal amplitude
800mV
±
10%
D.C. offset
0V
±
0.5V
Rise time (20-80%)
Fall time (20-80%)
Difference
< 270ps
< 270ps
≤
100ps
Return loss
>15dB
OUTPUTS (Channel 1 and 2)
Electrical
1.485Gbit/s HD-SDI
Connector Format
BNC 75ohm panel jack
Outputs
4
Peak-to-peak
signal amplitude
800mV
±
10%
D.C. offset
0V
±
0.5V
Rise time (20-80%)
Fall time (20-80%)
Difference
< 270ps
< 270ps
≤
100ps
Return loss
>15dB
INDICATOR LEDS
Not accessible to the Operator
Standard
Power
Power supplies valid
Fault
Board fault
Enhanced Monitoring Option
CPU
Valid CPU activity
For both data channels
PLL Lock
Output locked to input
standard
CRC Error
Data error
Line
Indicates line standard
Frame
Indicates frame rate
Prog/Int
Indicates progressive or
interlaced frames
RollCall™
‘Standard’ RollCall
monitoring options:
General alarm
Supply voltage levels
Board temperature
‘Enhanced’ RollCall
monitoring options:
For both data channels
CRC status
Line standard
Frame rate
Error rate
POWER CODE
1
WEIGHT
<750gm (Main Board plus
Interface Board)
OPTIONS
See page 2