SW5 and SW6
The two 8-way DIL switches allow various functions to
be set when an active front panel is not fitted. Note that
when an active front panel is fitted most switch settings
will be reflected by the front panel menu display or
indicators.
SWITCH SW5 (UP = OFF, DOWN = ON)
Positions 1 & 2 Input Type Select
Used with SW6 position 3
(Note 0=OFF, 1=ON X=Don’t Care)
Input
SW5 Pos 1 SW5 pos 2 SW6 pos 3
Digital A
X
0
0
Digital B
X
1
0
Parallel
X
X
1
Position 3
This position is not used
Position 4
This position is not used
Position 5
This position is not used
Position 6 Test
In the OFF position the unit operates normally; in the
ON position a test mode is enabled.
Positions 7 This position has no function.
Position 8
If this switch is in the OFFposition the unit will power-up
to the conditions set by switches SW4, SW5 and SW6.
Control Panels (Front+RollCall or Remote) will not
connect to the unit.
If this switch is ON the unit will power up as last
configured. Both Front and Remote control panels may
connect and control it.
SECTION 4
Operation
MDD550050398
Software Version 1.3.1 onwards 4.6