IQUDC30/IQUDC31/IQUDC32/IQUDC33
Operation Using the RollCall Control Panel
Issue 1 Rev 4
Page 94
© 2016 SAM
5.18.3 Ref/Output Logging
The Ref/Output Logging screen displays the current log information for the external reference
inputs, and the output of each processing channel.
The Reference field is present if a rear panel with external reference input connection is fitted.
Output 1 is always present on all variants of rear panel. Output 2 is present on dual-channel
product variants.
Note:
The outputs are not the physical connections to the rear panel, but the output of the
processing channels.
Log Field
Description
OUTPUT_
N
_TYPE=
The type of output as specified by the module’s configuration:
•
HD/SD SDI – SDI BNC serial input connection
OUTPUT_
N
_STATE=
The current output state:
•
OK – Input signal is good
•
Fail – Output signal error
OUTPUT_
N
_STANDARD=
The current output standard. See supported output standards
information.
Note:
Output 2 is only applicable to the IQUDC31 and IQUDC33.