BT-T080 Programming Manual
- 25 -
Hex
1B
52
n
Decimal
27
82
n
[Value range]
0
≤
n
≤
12
[Notes]
Select an international character set n from the following table:
n
Character set
0 U.S.A.
1 France
2 Germany
3 U.K.
4 Denmark
I
5 Sweden
6 Italy
7 Spain
I
8 Japan
9 Norway
10 Denmark
II
11 Spain
II
12 Latin
America
13 Korea
[ Default ]
n = 0
ESC V n Select/Cancel 90° clockwise rotation
[Function]
Select/Cancel 90° clockwise rotation
[Format] ASCII
ESC
V
n
Hex
1B
56
n
Hecimal 27 86 n
[Value range]
0
≤
n
≤
1, 48
≤
n
≤
49
[Notes]
Value of n is as following:
n
Function
0,48
Cancel the 90° clockwise rotation mode
1,49
Select the 90° clockwise rotation mode
• This command is effective only in standard mode.
• When select underline mode, the underline can not be 90° clockwise-rotated.
• Double-width and double-height commands in 90° rotation mode enlarge characters
in the opposite directions from double-height and double- width commands in normal
mode.
[ Default ]
n = 0
[Relative]
ESC !, ESC
[Example]
1B 40
1B 56 01