20
Section 4 - REPAIR & ADJUSTMENTS
4.5. BATTERY SERVICE
4.5.1. NEW BATTERY PREPARATION
1.
Remove battery from carton.
2.
Place battery in a well ventilated area on a level
non-concrete surface.
3.
Remove battery cell caps. Fill cells as required
with electrolyte (supplied with battery) to proper
level. Filling battery with electrolyte will bring the
battery to 80% charged state.
4.
With cell caps removed, connect battery charger
to battery terminals; RED to positive (+) and BLACK
to negative (-) terminal.
IMPORTANT:
Never place anything in battery other than
specified electrolyte.
5.
Slow charge the battery at 1 amp for 2 hours to
bring the battery to full charge.
6.
After charging, check level of electrolyte and add as
needed to bring to proper fluid level.
7.
Reinstall cell caps.
8.
Install battery into power unit.
9.
Connect positive (+) cable (red) first, from wiring
harness to the positive terminal (+) on battery using bolt
and nut provided in hardware bag. Connect negative (-)
cable (black) last, to negative terminal (-) on battery
using bolt and nut. Apply a small amount of grease
over terminals to prevent corrosion.
WARNING
DO NOT over fill battery with electrolyte. Shield the
positive terminal with terminal cover located on
battery harness. This prevents metal from touching
the positive terminal, which could cause sparks. The
electrolyte (acid) produces a highly explosive gas.
Keep all sparks, flame and fire away from area when
charging battery or when handling electrolyte or
battery. Electrolyte (acid) is a highly corrosive liquid.
Wear eye protection. Wash affected areas immediately
after having eye or skin contact with electrolyte (acid).
Battery acid is corrosive. Rinse empty acid containers
with water and mutilate before discarding. If acid is
spilled on battery, bench, or clothing, etc., Flush with
clear water and neutralize with baking soda. Never
attempt to charge battery while installed on the walk
behind. Never use “BOOST” chargers on the battery.
4.5.2. BATTERY SERVICE
1.
Remove battery.
2.
Place battery in a well ventilated area on a level
surface.
3.
Using distilled water, refill cells as required to
cover cell plates.
4.
With cell caps removed, connect battery charger
to battery terminals. Red to positive (+) terminal and
black to negative (-) terminal.
5.
Slow charge battery at 1 amp for 10 hours.
6.
If battery will not accept charge or is partially
charged after 10 hours of charging at 1 amp, replace
with new battery.
4.5.3. BATTERY STORAGE
If Walk Behind is to be stored out of season on its
rear bumper, it is recommended the battery be
removed, charged and stored.
1.
Remove battery.
2.
Perform battery service.
3.
Bring battery to full charge, if required.
4.
Store battery in an area away from the Walk
Behind on a wood surface. DO NOT STORE
BATTERY ON A CONCRETE SURFACE.
4.5.4. BATTERY TESTING
There are two types of battery tests: Unloaded and
Loaded. The unloaded test is the procedure that will
be discussed. It’s the simplest and most commonly
used. An unloaded test is made on a battery without
discharging current. To perform unloaded testing,
check charge condition using either a hydrometer or
voltmeter.
1.
Using a voltmeter, voltage readings appear
instantly to show the state of charge. Remember to
hook the positive lead to the battery’s positive
terminal, and the negative lead to the negative
terminal.
2.
A hydrometer measures the specific gravity of
each cell. The specific gravity tells the degree of
charge; generally, a specific gravity of about 1.265 to
1.280 indicates full charge. A reading of 1.230 to
1.260 indicates the battery should be charged. The
chart on the next page shows the charge level as
measured by syringe float hydrometer, digital
voltmeter and five ball hydrometer.
4.5.4. BATTERY
TESTING
Methods of Checking Battery Condition
State of Charge
Syringe Hydrometer
Digital Voltmeter
Five Ball Hydrometer
100% Charged w/ Sulfate Stop
1.280
12.80v
Five Balls Floating
100% Charged
1.265
12.60v
Four Balls Floating
75% Charged
1.210
12.40v
Three Balls Floating
50% Charged
1.160
12.10v
Two Balls Floating
25% Charged
1.120
11.90v
One Ball Floating
0% Charged
Less than 1.100
Less than 11.80v
Zero Balls Floating
Summary of Contents for RP216019KWV (7800199) operat
Page 24: ...24 PRIMARY MAINTENANCE ...
Page 25: ...25 PRIMARY MAINTENANCE ...
Page 26: ...26 PRIMARY MAINTENANCE ...
Page 27: ...27 PRIMARY MAINTENANCE ...