background image

15

Specifications

 
A digital copy of this manual can be found at:  

http://www.autonomic-controls.com/documents/Amplifiers/Manual_Instructions_Mirage_801e.pdf

Notes

•  When a command is sent to an ampli-

fier it will first be transmitted on the 
control bus and then returned to the PC 
(Home Automation System). If an error 
occurs an error will be returned instead 
of the original command. The PC (Home 
Automation System) needs to ignore its 
command when it is returned.

•  A Standby ON command implies that the 

amplifier is not muted, if the amplifier 
was previously Off, a mute command 
must follow the Standby command if it 
is muted.

•  Not all Command and Data commands 

are covered in this document. 

•  The expected reply for the "Send all 

Parameters" command (09) is >144 
bytes. All command fields listed in this 
document are contained in the reply. The 
reply also contains advanced commands 
not listed in this document. The home 
Automation or PC’s buffer should be 
large enough to receive and process the 
144-byte reply. 

a.  Zone 2 links to Zone 3.

b.  Since Zone 2 is no longer linked to 

Zone 1, Zone 1 will no longer be 
linked to Zone 2.

c.  Since Zone 3 is no longer linked to 

zone 4, Zone 4 will no longer be 
linked to Zone 3.

Example strings:

•  010A01: Standby ON command for Zone 

10 amplifier.

•  012A01: Standby ON command for Zone 

10 preamplifier.

•  060002: +2db Treble setting on Zone 0.

•  03IF02: Select Source 7 on Zone 31.

©2006–2019 

Autonomic Controls, Inc.

 Autonomic, eAudioCast, and TuneBridge are registered trademarks of Autonomic Controls, Inc.  

All other trademarks are property of their respective owners. Specifications are based on current revision and may change without notice.   013119

Rated Output Power (FTC)  
All Channels

55W per channel / 8Ω loads
75W per channel / 4Ω loads

Total Harmonic  
Distortion (THD)

0.1% (50 Watt, 8 Ω load)

Damping Factor (8Ω load)

10

Speaker Impedance (Z1 - Z6 L/R)

4Ω–8Ω

Analog Input Sensitivity 
(S1 - S8 L/R)

0.75V RMS (Vol 100, Gain 0dB, 55W Output)

Analog Input Impedance 
(S1 - S8 L/R)

22KΩ

Digital Input sensitivity

0dBFS

Pre Amplifier Output Level and 
Impedance (Z7 & Z8 L/R)

+14dB 

Frequency Response

48 KHz sample rate: 10Hz - 22 KHz
96 KHz sample rate: 10Hz - 42 KHz

Tone Control

±12dB, 100Hz (Bass) 
±12dB, 10kHz (Treble)

Signal to Noise Ratio

95dB (IHA-A, 0.75V input / unbalanced)

IR Output

(10) 3.5mm Jack: IR1 - IR8 current limited to 25mA

Source Inputs

(12) Digital Coaxial RCA, (8) Analog (L/R) RCA, (4) TOSLINK

Ethernet

(2) 100Base-T, MAIN IN and Switch EXT OUT

USB

(1) USB mini-B female 5 pin

Data

(1) 4 pole 3.5 mm terminal block connector (Data,12V, IR,0V)

Controllers

(8) RJ45 sockets Keypad controller ports      

BUS RUN

(1) 4 way terminal block (0V, IR 12V & Data)

Amp On & PG Control

(1) 10 way terminal plug with Amp ON 1 - 8 and  
(2) page preset contact closure inputs: PG1 & PG2

Zone Triggers & Presets

(1) 12 pole 3.5 mm terminal block connector  
(Zone trigger 0V out, Zone trigger 1 - 8 12V out, Common, Preset 1 - 2 in)

Power Supply

110–240V AC 50–60Hz

Power Consumption

650W

Standby Power Consumption

6W

Dimensions with feet

4.0” H x 17” W x 15” D (10.2cm x 43.2cm x 38.1cm

Weight

15.4 lb. (7 kg)

Height including feet

105 mm

Touch Panel Display

2.4" color LCD touch panel display for menu guided control and programming.

Zones

(8) zones
Expandable to 96 zones, attaching additional M-801e or M-401e amplifiers

Acknowledgments – FreeRTOS – uIP

The M-401e firmware is based in part on FreeRTOS.org

 V5.0.2 and the uIP TCP/IP stack. 

For more information on FreeRTOS.org

 please visit http://www.freertos.org. Source code for FreeRTOS.org™ can be downloaded from their official website. 

The following copyright and statements for uIP TCP/IP stack are required by license: Copyright © 2001-2003, Adam Dunkels. All rights reserved.

1.Redistribution and use in source & binary forms, with or without modification, are permitted provided that the following conditions are met:
2.Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
3. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. The 

name of the author may not be used to endorse or promote products derived from this software without specific prior written permission.

 
THIS SOFTWARE IS PROVIDED BY THE AUTHOR "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT 
LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS

Summary of Contents for Mirage Autonomic MAS M-801e

Page 1: ...MAS m 801e 4 room Digital Amplifier with eAudioCast ...

Page 2: ......

Page 3: ...tructions 1 Precautions 1 Declaration of Conformity 2 Features 3 Front Panel Guide 4 Rear Panel Guide 5 Typical System Configuration 6 Multiple Amplifier Stacks 8 Controller Wiring 9 Menu Navigation 10 Ethernet Protocol 13 Specifications 15 ...

Page 4: ...at the plug is readily oper able easily accessible at all times If you do not intend to use the unit for an extended period remove the power cord from the AC outlet 4 Earth The unit is defined as Class1 in EN60065 low voltage directive and MUST BE EARTHED Connect only to a mains socket outlet with protective earth and only use the power cord supplied Finland Laite on Liitettävä suojamaadoi tuskosk...

Page 5: ...nable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful inter...

Page 6: ...ts Two IR ports 9 10 are the sum of all IR sources and control the All zone source components Ethernet and IR Control The M 801e amplifier may be controlled and monitored via Ethernet An M 801e amplifier may receive IR directly from the front panel receiver There are zone specific IR commands and also a set of global IR commands The commands are ON OFF Standby toggling Mute Volume Up Volume Down S...

Page 7: ...d at www Autonomic Controls com Support 3 Power Indicator The power indicator glows blue when ever AC power is applied 4 2 4 Color LCD Touch Panel display LCD touch panel display for menu guided control and programming The display is dimmed to Off after 15 min utes of inactivity 5 Chassis Feet Set high enough to provide unrestricted air flow through the chassis for convec tion cooling 6 Rack Mount...

Page 8: ...0 100 Base T secondary port for connection to another eSeries Amplifier s MAIN IN Ethernet Port 8 Zone Pre Amplifier Out Analog Audio L R zone 7 8 outputs 9 Analog Input Terminals Analog audio L R inputs 10 IR Emitter Ports 3 5mm mono jacks IR9 IR10 ports output the combined IR1 IR6 infra red strings Ports are not usable but are future ready for IR routing 11 Optical Digital Inputs Optical TOSLINK...

Page 9: ...Typical System Configuration CD Player FIGURE 1 Zone 1 Gym KP 6 KP iOS Tablet To Ethernet Router Zone 2 Study Zone 3 Lounge Autonomic Media Server Satellite Receiver Tuner CD Player 6 ...

Page 10: ...ource control functionality Speakers Speakers in each zone are connected to the amplifier by Home Run speaker cables Source Equipment The M 801e amplifier has eight stereo RCA audio inputs for connecting to source equipment These input channels feature coax digital inputs If a signal is present on the digital input it takes precedence over the analog input There are four additional Digital only in...

Page 11: ...Multiple Amplifier Stacks Linking to the next M 401e or M 801e Multi Zone Amplifier FIGURE 2 Autonomic Media Server Satellite Receiver Tuner CD Player To Ethernet Router 8 ...

Page 12: ...rces if connected to the Home network Router or Switch Ensure all amplifiers using same the amp ID in the stack The source equipment audio inputs must be plugged into the first amplifier where they are buffered and sent to the next amplifier in the stack The maximum recommended expansion is 24 units Fig 2 shows a stack of M 801e with Source connections to first amplifier where they are converted t...

Page 13: ...age When the More button is pressed and held for more than 1 second a More Functions page opens There are three Zone specific functions that when selected navigate to setup pages EQ Levels Zones There is also a System function which is not zone specific The System page is covered later Note System functions may be accessed via any of the Zones More Functions pages The Back Arrow button returns to ...

Page 14: ...can be reduced over the range from 100 to the minimum of 2 using the slider or Up Down button The Back arrow button returns to the More Functions page NAME AQUARIUM ZONE 100 EDIT ZONE LINKING 2 ABC 3 DEF 1 5 JKL 6 MNO 4 GHI 8 TUV 9 WXYZ 7 PQRS 0 _ ZONE NAME AQUARIUM 50 50 MAX VOLUME BALANCE Zones Setup Page Zones setup page allows you to edit the name and set the Zone coding There is also a button...

Page 15: ... if the gain is set to high and distortion is detected Select the Back arrow to return to the System Settings Page NETWORK SETTINGS IP Address Subnet Mask DNS Server Default Router Mac Address 192 168 001 010 255 255 255 000 192 168 001 254 192 168 001 254 12 34 56 78 9A BC DHCP STATIC RESET RESTORE DEFAULTS SYSTEM REBOOT RESTORE DEFAULTS Are You Sure YES NO Network Settings Page Network setting a...

Page 16: ...e Up 12 Volume Down 14 Request Device information 1C Zone Name 1D Preamplifier Volume Mode 26 Volume BCD format Zone Amplifiers are encoded with up to 96 zones The zone byte is used for checking if the command is applicable to the device receiving the command and if so for optionally selecting a sub device e g a bank or part of a device All Zones are addressed using FF The lower 5 bits of the zone...

Page 17: ...ange Bass 05 F4 0C 12db 12db Treble 06 F4 0C 12db 12db Balance 07 EC 14 Left 20db Right 20db Send all parameters 09 XX Value Ignored Amplifier features 0C 00 Loudness Disabled 01 Loudness Enabled Maximum Volume Limit 0D 00 A0 Range Volume Up 11 XX Value Ignored Volume Down 12 XX Value Ignored Zone Name 1C Data field contains the ASCII string Preamplifier Volume Mode 1D 00 A0 Range FF Independent M...

Page 18: ...HA A 0 75V input unbalanced IR Output 10 3 5mm Jack IR1 IR8 current limited to 25mA Source Inputs 12 Digital Coaxial RCA 8 Analog L R RCA 4 TOSLINK Ethernet 2 100Base T MAIN IN and Switch EXT OUT USB 1 USB mini B female 5 pin Data 1 4 pole 3 5 mm terminal block connector Data 12V IR 0V Controllers 8 RJ45 sockets Keypad controller ports BUS RUN 1 4 way terminal block 0V IR 12V Data Amp On PG Contro...

Page 19: ...06 2019 Autonomic Controls Inc Autonomic and TuneBridge are registered trademarks of Autonomic Controls Inc All other trademarks are property of their respective owners 013119 MirageAudioSystem com eSeries ...

Reviews: