CEBORA S.p.A.
9
♦
Gas begins flowing from the torch, for as long as the button is held down.
Correct?
♦
Gas continues to flow from the torch for the duration of the post-gas time set, led
(X) lit, even after the start button is released.
NO (see 3.3.3, 3.3.4, 3.3.5).
YES
Press the start button and hold it down for approximately 5 seconds.
♦
Gas output begins; the high frequency is then generated to start the arc, as well as
the power source output DC voltage (AC voltage is generated only if output
current in present).
Correct?
♦
After approximately three seconds, the output voltage and high frequency are no
longer generated (TIG operation stops if there is no current at the power source
output after start) and the post-gas stage begins.
NO (see 3.3.6, 3.3.7).
YES
Use the knob (AA) to set the current based on the welding you intend to perform.
Move the torch near the workpiece and press the torch trigger.
♦
Begin welding. Turn the knob (AA) or the torch potentiometer to obtain the
current level suitable for the type of welding to be done.
Correct?
♦
During welding display (Z) indicates the welding current.
NO (see 3.3.3, 3.3.8).
YES
Release the torch start button.
♦
The arc shuts off immediately (if long ramp times are not set).
Correct?
♦
Gas continues to flow for the entire post-gas time.
NO (see 3.3.5).
YES
REGULAR OPERATION.
3.302.221
15/01/07
Summary of Contents for TIG 250 AC-DC
Page 1: ...CEBORA S p A 1 TIG 250 AC DC POWER SOURCE art 236 76 SERVICE MANUAL 3 302 221 15 01 07 ...
Page 35: ......
Page 37: ......