5

Rotary Switch

The Rotary Switch is the main control for the M2 Scope/Meter. It configures 
the meter for the type of test, or function, to be performed. Each function is 
indicated by a graphic icon, as explained in the table below:

Table 1-2 

Rotary Switch options

Function

Icon

Description

Off

Switches power to the M2 Scope/Meter off. The 
switch should be in this position when the tool is not 
being used to prevent battery drain.

Volts DC

Measures direct current (DC) voltages within a range 
of zero to 1000 volts. This setting is also used to 
measure frequency (hertz), duty cycle (%), time 
period (cycle, ms), and pulse width (Pw).

Volts AC

Measures alternating current (AC) voltages within a 
range of zero to 1000 volts. This setting is also used 
to measure frequency (hertz), duty cycle (%), time 
period (cycle, ms), and pulse width (Pw).

Resistance

Measures the DC resistance to current in ohms in a 
range of zero to open circuit (infinite).

Continuity/
Diode Check

Performs dual tests; circuit continuity and diode test 
(forward drop). The “S” (special function) soft key 
switches between the two tests.

Auxiliary

Performs three auxiliary tests; current (amperes), 
pressure/vacuum, and temperature. Use the “S” 
(special functions) and “Range” soft keys to switch 
between the tests and output units. Pre-approved 
sensors must be used to take valid measurements.

Capacitance

Measures capacitance in nanofarad (nF), millifarad 
(mF), and microfarad (

μ

F).

Oscilloscope
(Waveform 
Viewer)

Configures the M2 Scope/Meter to perform as an 
oscilloscope, or waveform viewer.

Remote 
Functions

Configures the M2 Scope/Meter to be operated 
through a remote Display Device. Readings are only 
shown on the Display Device screen. The controls on 
the front panel of the M2 Scope/Meter become 
inoperative when the rotary switch is in this position.

Summary of Contents for Scope/Meter M2

Page 1: ... 2012 Snap on Incorporaated All rights reserved EAZ0063L39A Rev A M2 Scope Meter Quick Start Guide ...

Page 2: ...and care The M2 Scope Meter User Manual is available on line at http www1 snapon com diagnostics us UserManuals The M2 Scope Meter can be used as a stand alone meter or be wirelessly paired to a remote Display Device so that test results can be viewed on a larger screen Refer to the User Manual on the website shown above for instructions on pairing units IMPORTANT Be sure to read and understand th...

Page 3: ...right side Recharge the internal battery when the display indicates a low charge To recharge the internal battery 1 Connect the battery charger supplied with your M2 Scope Meter Kit to an appropriate service outlet 2 Plug the small cable end into the single port on the top of the unit Main Body The main body of the screen shows test results and screens will vary by test and tool setup Function Too...

Page 4: ...surement range when in Volts DC Volts AC Resistance Auxiliary capacitance graphing or scope modes Volts DC Volts AC Resistance Capacitance F4 Available only in graph and oscilloscope modes this soft key is used to change the time base Waveform Viewer S A short press of the Special Functions key switches between functions Hz Pw etc a long press returns to the original setting Available functions va...

Page 5: ...cycle ms and pulse width Pw Resistance Measures the DC resistance to current in ohms in a range of zero to open circuit infinite Continuity Diode Check Performs dual tests circuit continuity and diode test forward drop The S special function soft key switches between the two tests Auxiliary Performs three auxiliary tests current amperes pressure vacuum and temperature Use the S special functions a...

Page 6: ...ess and hold to return to the default setting Range moves down through the list of available voltage scales Graph moves down through the list of available time bases Trigger In the trigger mode the soft keys perform the following functions F2 switch the trigger between the rising positive and trailing negative edge of the waveform F3 a short press incrementally increases the trigger voltage level ...

Page 7: ... amperage Position Repositions the baseline of the trace vertically on the screen A short push of the F2 key moves the trace up incrementally A long push of the F2 key places the trace at the midpoint of the scale A short push of the Min Max key moves the trace down incrementally A long push of the Min Max key places the trace at 10 of the scale A short push of the F3 key moves the trace up increm...

Page 8: ...not pull on the wire because it can damage the leads Pull on the plug Three insulated alligator clips that attach to the test leads are included The insulator boots are colored to match each test lead To install an alligator clip 1 Remove the collar from the probe by threading it counterclockwise off of the probe tip Store the collar in a safe place while not in use 2 Thread the alligator clip ont...

Reviews: