Snap
‐
on
EEWB330A
Handspin
Wheel
Balancer
Option2:
Do
not
turn
the
tire
over
on
the
rim.
Press
the
FINE
key
(3).
The
result
is
recalculated.
Reading
OP.7
‐
II
or
H0
or
H2
appears.
To
go
to
II
‐
OP.7
(turning
over
the
tire)
press
the
FINE
key
(3)
again.
Option3:
Abort
optimization.
Press
the
STOP
key
(5)
to
exit
the
OP
program
and
return
to
the
balancing
program
.The
imbalance
on
the
wheel
is
shown
on
the
readout.
Balance
the
wheel
according
to
the
readings.
Reading
OP.7
‐
II
(Fig.5
‐
37).
Read
just
the
tire
on
the
rim
(the
right
display
bars
light
upper
manently).Option1:
Read
just
the
tire
on
the
rim
(normal
program).Read
just
the
wheel
following
the
right
direction
indicator
and
make
a
double
mark
on
the
right
side
of
the
tire
exactly
perpendicular
to
and
above
the
main
shaft
(Fig.5
‐
38).
Remove
the
wheel
from
the
machine.
Read
just
the
tire
on
the
rim
until
the
double
mark
coincides
with
the
valve(Fig.5
‐
39).
Clamp
the
wheel
on
the
balancer
and
readjust
so
that
the
valve
is
exactly
perpendicular
to
and
above
the
main
shaft.
Press
the
ENTER
key
(1)
to
acquire
the
valve
position.
Reading
OP.8
appears
(Fig.5
‐
34).
Spin
the
wheel
(START)
(check
run).
If
balancing
optimization
(silent
running)
has
been
carried
out
correctly
according
to
the
program
cycle,
after
the
check
run
the
machine
automatically
returns
to
the
type
of
weight
positioning
previously
selected
and
indicates
the
residual
dynamic
imbalance
on
the
wheel.
Balance
the
wheel
according
to
the
readings.
Both
optimization
and
balancing
are
accomplished.
MessageE9
means
that
at
least
one
error
occurred
during
the
optimization
cycle.
Press
the
STOP
key
(5)
to
exit
the
optimization
program
and
repeat
optimization
if
necessary.
Option2:
Do
not
adjust
the
tire
on
the
rim
Press
the
STOP
key
(5)
to
exit
the
OP
program
and
return
to
the
balancing
program.
The
imbalance
on
the
wheel
is
shown
on
the
readout.
Balance
the
wheel
according
to
the
readings.
Reading
H0.
Press
the
STOP
key
(5)
to
exit
the
OP
program
and
return
to
the
balancing
program.
The
imbalance
on
the
wheel
is
shown
on
the
readout.
Balance
the
wheel
according
to
the
readings.