9
Abb. 16:
Control panel/ DMX-Signal
Fig. 17: Adjusting pump value
Fig. 18: Adjusting fan value
5.3.2.1 Adjusting the DMX start address
Press the Mode button at the control panel until three
figures appear on the LED display
Adjust the required start address (001-511) by pressing the Up or
Down-button.
Save the start address by pressing the Enter button once.
5.3.3 Standalone mode
The
Smoke Factory – Hazer II
can be used in the standalone mode.
In this mode all data for the pump and the fan must be adjusted directly at the machine.
Press the Mode button at the control panel until a “P”
and two figures appear on the LED display
Adjust the desired data (1 - 99%) by pressing the Up/Down-Button.
By pressing the Enter-Button you turn off the smoke machine and
the optional fan.
Pressing again the Mode-button
leads you to the options
¾
P = Pumpe
¾
F= Fan
5.3.2.2 Adjusting the values for the pump and the fan
Adjustments after activating the Tour Hazer are not necessary. The performance of the pump as well as the
fan can be adjusted via control panel from 1% to 99%.
Press the Mode button again until a „
F“
and two figures
appear on the display.
Adjust the desired data (1 - 99%) by pressing the Up/Down-Button.