This  heater  is  designed  to  be  installed  into  suspended  T-bar  and  plasterboard  ceilings  (The 
minimum height of the void into which the unit will be installed should be a minimum of 250mm). 
 
 

User Information: 

This heater must not be installed in wet rooms or other high humidity areas.  
 
This heater is designed for use on standard two-pipe pumped central heating systems with a 
maximum water temperature of 86° C and a maximum pressure of 6 bar (88lbs/in²). 
Pipe connections are 22mm and either pipe may be used as flow or return.  
 
This heater is classified as a fixed appliance and the electrical connection should be via a 3A fused 
spur. The fused spur must 

not

 be directly below the heater but should be accessible after 

completion of the installation. This heater must be earthed.  
It is recommended that this heater is wired via a remote room thermostat. 
 
To avoid the possibility of vibration this heater must be fitted to a flat even surface. 
 
This heater is fitted with a 35°C Low Limit Stat (L.T.C).  
 
To conform to Building Regulations Part L (Part J in Scotland), a remote room thermostat can be 
used in conjunction with this heater. Refer to the instructions supplied with the thermostat.  

 

Please note the guarantee may be invalidated if this product is not installed and used in 

accordance with these instructions.

 

 

For further details please contact our Technical Support on 01245 324560. 

 

 
 
 
 
 
 
 
 

              

Figure 1 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 

Fault Finding 

 
1) 

The fan does not run on any switch setting.

 

a) 

Check the power supply is switched ON. 

b) 

Check the fuse in the fused spur. 

c) 

Check the wiring at the fused spur. 

 
2) 

No heat output. 

a) 

Vent any trapped air from the system (with the heating system turned OFF). 

b) 

Check the central heating is switched ON. 

c) 

If a thermostat is fitted ensure it is calling for heat. 

d) 

Balance the central heating system if installed on the same circuit as panel radiators and 
increase the circulating pump speed if required. 

e) 

Increase the boiler water temperature. 

 
In the event of difficulty please contact our technical help-line on 01245 324560. It will be helpful if 
you do not disconnect the heater from the central heating system. 
 
 

Information and advice 

A product brochure containing full technical specifications and list prices is available to 

download from our website or in hard copy from our office. Also available on our website are 

price lists, individual product datasheets, installation & user guides, where to buy, who to 

contact and a media centre. 

 

Alternatively contact our office 9.00am to 5.00pm Monday to Thursday, 9.00am to 4.00pm on 

Friday. 

 
 

 

Optional Accessories  

 
Optional accessories are available to offer additional control or functionally not offered by the heater 
in its standard configuration.  
 

Electrical Accessories 

External Control Harness                                                                                        EXTCH 

Allows for the standard unit controller to be relocated externally from the heater. 

Adjustable low temperature cut-out                                                                      UVCALTC T3 

This enables the end user to precisely select the temperature at which the fans will switch on when 
combined with different heat sources. 

Miscellaneous Accessories   

Caspian 22mm Flexible Hoses                                                                               CAS22FH 

Replacement air filters.

 

For accessories or spares please contact either your supplier or Smith’s Environmental 
Products Ltd.

 

Summary of Contents for CASPIAN SKYLINE CT60 EC

Page 1: ...s Environmental Products Ltd reserve the right to alter specifications without prior notice Issue 5 8 June 2017 Suitable for Installation within a ceiling void Installation User Guide User Information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervi...

Page 2: ...k the power supply is switched ON b Check the fuse in the fused spur c Check the wiring at the fused spur 2 No heat output a Vent any trapped air from the system with the heating system turned OFF b Check the central heating is switched ON c If a thermostat is fitted ensure it is calling for heat d Balance the central heating system if installed on the same circuit as panel radiators and increase ...

Page 3: ...ase note in the event of an engineer s visit Smith s Environmental Products Ltd reserve the rights to apply a call out charge should the fault prove to be with the system or installation and not the heater appliance 6 Preparation The following items should be included in the carton Caspian Skyline CT60 EC unit Grille Installation User Guide X4 No 8 Screws Other items required for a successful inst...

Page 4: ...provided screws see figure 4 Once secured the grille can be open and closed by pushing against the grille on the side with the closure Once to open Once again to close care should be taken not to bend the grille 6 Proceed to page 5 for plumbing and electrical connection Figure 4 4 Plumbing connection Pipe connections to the heat exchanger should be made using 22mm pipe and fittings Isolating valve...

Page 5: ...provided screws see figure 4 Once secured the grille can be open and closed by pushing against the grille on the side with the closure Once to open Once again to close care should be taken not to bend the grille 6 Proceed to page 5 for plumbing and electrical connection Figure 4 4 Plumbing connection Pipe connections to the heat exchanger should be made using 22mm pipe and fittings Isolating valve...

Page 6: ...ase note in the event of an engineer s visit Smith s Environmental Products Ltd reserve the rights to apply a call out charge should the fault prove to be with the system or installation and not the heater appliance 6 Preparation The following items should be included in the carton Caspian Skyline CT60 EC unit Grille Installation User Guide X4 No 8 Screws Other items required for a successful inst...

Page 7: ...k the power supply is switched ON b Check the fuse in the fused spur c Check the wiring at the fused spur 2 No heat output a Vent any trapped air from the system with the heating system turned OFF b Check the central heating is switched ON c If a thermostat is fitted ensure it is calling for heat d Balance the central heating system if installed on the same circuit as panel radiators and increase ...

Page 8: ... instructions It is important to register within 7 days This will ensure you receive a prompt and efficient service if your product requires attention within the guarantee period If you do not register your product you will be required to produce a proof of purchase prior to receiving this service If you experience any problems with the use of your product please contact our after sales office on ...

Page 9: ...survey the response will help us to serve your needs more effectively Please return by fax to 01245324422 Quality Control Manager Ron Brown ron brown smithsep co uk User Details User Name Mr Mrs Miss Ms Other Initials Surname Address Post Code Telephone Product Model installed e g Space Saver SS5 Room Installed e g Kitchen Your details will only be held by Smiths Environmental Products Ltd and use...

Page 10: ...s Environmental Products Ltd reserve the right to alter specifications without prior notice Issue 5 8 June 2017 Suitable for Installation within a ceiling void Installation User Guide User Information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervi...

Reviews: