THERMOSTAT CONTROLLER QUICK SET UP
1. Ensure the heater is correctly installed and connected to the mains power
supply.
DO NOT TURN THE MAINS POWER ON AT THE WALL UNTIL INDICATED IN
THE INSTRUCTIONS BELOW.
2. Remove the thermostat from the box and packaging. Remove the two
screws to access the back of the SLVT-B thermostat Controller. The clear
plastic tag should be pulled out from the end of the battery holder. The
screen should now show the current room temperature. Note: If you are
using any of the advanced features, these should be set now (see separate
instruction detail packaged with controller)
3. Set the heater fan switch to ON (leave the mains power OFF at the wall)
Turn ON the mains power at the wall and within 20 seconds press and hold
the large ON/OFF button on the SLVTB thermostat controller, keep pressing
button, PAIR and then TEST will appear on the screen. Once TEST appears on
the screen release the button and the fan in the heater should run.
Note: Failure to switch on the mains power and press the controller ON/OFF
button within 20 seconds will result in the heater and controller not pairing
and the pairing process should be restarted from step 3
5. To exit the pairing mode, press the ON/OFF button on the SLVTB
thermostat controller ONCE (DO NOT HOLD THE BUTTON IN). The room
temperature will now be shown.
6. Set the heat output switch on the side of the heater to the desired
position.
7. Press the large ON/OFF button on the SLVTB
controller ONCE (DO NOT HOLDTHE BUTTON IN). You will see a heating
symbol appear in the bottom left hand corner of the screen; this indicates
the thermostat is turned on.
8.Using the UP and DOWN
symbols buttons on the SLVTB
controller set the temperature
to the desired setting. Press
the up arrow to increase the
target temperature or the
down arrow to decrease the
target temperature.
Providing the target temperature is higher than the room temperature the
heater will operate.
Note: If the heat symbol flashes the target temperature of the SLVT-B
thermostat controller is lower than the current room temperature – if the
heat symbol is solid the SLVT-B thermostat controller target temperature is
higher than the current room temp
OPERATION
The lower right-hand switch connects the mains supply to the fan motor
(giving cold air flow) and energizes the heat control switches.
Note: wireless controller must be in the on position for the heater to work.
HEAT CONTROL
When the centre switch (marked with 1 bar) is depressed the output is 1kW.
When top switch (marked with 2 bars) is depressed the heat output is 2kW.
When both switches are depressed the heat output is 3kW.
Note: for all heat settings the lower right-hand must be set to on (fan)
MAINTENANCE
ALWAYS ENSURE THAT THE MAIN EXTERNAL ELECTRICITY SUPPLY IS
SWITCHED OFF BEFORE ATTENDING TO THE SERVICING OF THE UNIT.
To obtain the best results from the Heater it is necessary to avoid any build-
up of dust or dirt within the unit or on the air inlet grille. For this reason the
unit should be cleaned regularly, paying particular attention to the removal
of dirt build-up on the back of the fan rotor blades.
The removal of dust and dirt is best achieved using a soft brush.