L1
N1
L2
N2
The electrical supply to these units should be via 2.5mm² single strand
3 core cable via a switch fused isolator fused at 20Amps.
6
To mount the heater appliance via suspension rods or chains.
A ceiling tile spacer is available as an accessory. This kit allows the facia to
protrude 85 mm beneath the finished ceiling tile, matching the profile of the
Skyline
®
CT18 hydronic model. A Surface mounting kit is also available which
provides a a complete four sided trim whne fitted to a solid ceiling.
7. If the mounting area is to align with a false or suspended ceiling panel, then
the holes must be centred to the panel.
8. Cut the suspension chains or rods to the required length for the installation.
Secure to the mounting surface.
9. Secure the lower ends of the chains or rods to the top four corners of the
heater appliance. Adjust the lengths of the chains or rods as necessary to
ensure the heater appliance is true and level.
10. Refer to the section under Electrical Connections.
11. Replace and secure the panel marked Electrical Connections.
12. Replace the facia and ensure it is secured with all the original screws.
3
600
600
248
176
426
87
All dimensions in mm.