background image

Issue 001 - April 2020  |  SmithsEP.co.uk  |  3

Declaration of conformity

EC Declaration of conformity
We, Smith’s Environmental Products Limited  
1-2 Blackall Industrial Estate 
South Woodham Ferrers 
Chelmsford 
Essex CM3 5UW 
Tel: 01245 324900 Fax: 01245 324422

Declare under sole responsibility that the products:

Product name:  

Caspian

Product range:  

Caspian Smart Control Range - Caspian UV, 
Caspian FF, Caspian EXT, Caspian SL, Caspian 
TT, Caspian UVC sizes 60, 90, 120, 150 & 180

Conform to the following European  
Union directives: 

Low Voltage Directive 2014/35/EU  
Safety of household electrical appliances:  
EN 60335-2-80:2003, +A1:04 +A2:09 
EN 60335-1:2012 +A11:14  +A13:17 +A14:19 
+A1:19 +A2:19

Electromagnetic compatibility (EMC)  
EN 55014-1:2017 
ETSI EN300 328: V2.1.1:2016 
EN55014-2:2015

This Declaration is made on behalf of Smith’s 
Environmental Products Limited.

 

Salus controller 

The Salus controller independently complies with 
the essential requirements and other relevant 
provisions of Directives 2014/30/EU, 2014/35/EU, 
2014/53/ EU and 2011/65/EU. The full text of the 
EU Declaration of Conformity is available at the 
following internet address: www.saluslegal.com.

Symbols

This manual contains information and 
prescriptions marked by the following symbols.

Ignoring these safety provisions 
marked by the symbol “caution: 
hazard” may endanger the safety 
of people.

Ignoring these safety provisions 
marked by the symbol “caution: 
electricity” may endanger the 
safety of people, as well as the 
integrity of things.

The removal of the screws can 
cause the output of hot fluids 
under high pressure from heating 
system. Drain the system or close 
the isolating valves.

High temperature surface. Take 
utmost care to prevent people 
from getting in contact with the 
hot surfaces of the appliance.

Summary of Contents for Caspian EC 120

Page 1: ...01 April 2020 SmithsEP co uk 1 Issue 001 April 2020 ENGLISH UK IRL SmithsEP co uk Caspian EC variants with Smart Controls Installation commissioning and user manual 60 90 120 150 180 EC Series Fan Con...

Page 2: ...earthed To avoid the possibility of vibration these units must be fitted to a flat even surface Please note that the guarantee may be invalidated if this product is not installed and used in accordanc...

Page 3: ...is made on behalf of Smith s Environmental Products Limited Salus controller The Salus controller independently complies with the essential requirements and other relevant provisions of Directives 201...

Page 4: ...e or if it is malfunctioning or it is dropped or damaged in any manner Inspect the appliance in accordance with manufacturers instructions The appliance should not be electrically supplied if there is...

Page 5: ...y protected by a Residual Current Device RCD or Ground Fault Circuit Interrupter with a rated residual operating current not exceeding 30mA 10 Prior to any modification being made to the equipment it...

Page 6: ...0 270 A Electrical supply in this side Model A 60 595 90 895 120 1195 150 1495 180 1795 Pipe centres Caspian UV Caspian SL 110 66 45 235 660 135 A Electrical supply in this side Model A 60 595 90 895...

Page 7: ...Issue 001 April 2020 SmithsEP co uk 7 110 65 45 235 1800 270 A Electrical supply in this side Model A 60 595 90 895 120 1195 150 1495 180 1795 Pipe centres Caspian EXT...

Page 8: ...8 SmithsEP co uk Issue 001 April 2020 Control mounting options configurations Predetermined at time of order Internally mounted tamper proof Wall mounted remote Flush mounted...

Page 9: ...ALVE GREEN GREEN GREEN GREEN GREEN BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE RED RED RED RED GREY GREY GREY WHITE WHITE WHITE BROWN BROWN BROWN BROWN BROWN BLUE BLUE B...

Page 10: ...7 0 21 0 Model Heat Output at 65 Heat Output at 60 Heat Output at 55 Heat Output at 50 Low kW Med kW High kW Low kW Med kW High kW Low kW Med kW High kW Low kW Med kW High kW CASPIAN 60 2 3 3 2 4 2 2...

Page 11: ...g based on BS EN442 using mean water temperature 18 C entering air temperature 10 temperature drop Mean water temperature C EAT C 80 to 40 15 1 10 21 0 93 Correction factors Temperature drop C 20 15 1...

Page 12: ...cation Flush mounted and Internal mounted control options are suitable for floor standing and other low applications Wall mounted remote control option should be used for wall and ceiling mounted appl...

Page 13: ...Issue 001 April 2020 SmithsEP co uk 13 Notes...

Page 14: ...sed Pipework must only enter in intended cut outs or knockouts on the header connection side of the heater Note 15mm pipework suitable for heating outputs up to 12kW 22mm should be used where output e...

Page 15: ...OFF F3 F2 F1 V2 V1 N L SALUS FC600 S2 COM S1 UP 60 Fig 4 Fig 1 Fig 2 Fig 3 Fig 5 Fig 6 3 Amp fused spur Supply L N 5 Electrical supply and electrical connection Electrical supply to the unit must be n...

Page 16: ...mostat will remain internally to the unit See wiring diagram S2 and C connections Master slave wiring hard wire A number of units may be controlled from one thermostat For connection details please se...

Page 17: ...connection offline mode Go to https salus controls com uk product fc600 downloads for the full PDF version of the manual Quick user guide for Wi Fi Thermostat Key Function Increase Button Decrease But...

Page 18: ...nsor indicators 23 Sensor indicators 24 Room setpoint temperature 25 Setpoint temperature indicator Schedule Mode Temporary Override Permanent Override LCD Icon descriptions Getting started All units...

Page 19: ...p arrow followed by the tick confirm button See image 1 and 2 M M M M 8 6 5 7 M M 3 4 4 5 Select the thermostat mode although this unit is heating only by setting heating and cooling allows the use of...

Page 20: ...n the App 7 8 Note To view detail of set up operation and parameters please consult the full manual at https salus controls com uk product fc600 downloads Temporary override M 2 Note The temporary ove...

Page 21: ...ll your settings Factory reset will only take effect on the thermostat you are working on 2 4 6 8 M M M M 1 2Sec 2Sec 2Sec 5 7 3 User Guide For further information and to view detail of set up operati...

Page 22: ...culty please contact us on 44 0 1245 324560 It will be helpful if you do not disconnect the heater from the central heating system Maintenance Warning Isolate from the electrical supply before perform...

Page 23: ...register your product you will be required to produce proof of purchase prior to receiving service For more details please visit our website SmithsEP co uk Disposal As part of the policy of continuou...

Page 24: ...ists All products are available nationally from Builders Merchants Plumbers Merchants Heating Equipment Distributors and Kitchen Equipment Distributors In the event of difficulty please contact us or...

Reviews: