background image

Issue 001 - April 2020  |  SmithsEP.co.uk  |  23

Accessories 

Air inlet filters for all models

Universal Gateway Hub UG600 for use with 
internet App control

For accessories or spares please refer to our price 
list, contact your supplier or Smith’s Environmental 
Products Ltd.

Registering your product

Thank you for purchasing a Smith’s product. It has 
been designed and manufactured to the highest 
quality standards to ensure it gives you efficient 
and trouble-free service for many years. We are 
committed to achieving the highest standards and 
our faith is supported by a free parts and labour 
guarantee with every product.

For more information on the warranty period 
for this product please visit our website  
smithsep.co.uk/product-registration/

This gives you the peace of mind that in the 
unlikely event of product failure, we will repair 
or replace the product completely free of charge 
providing the product has been installed, used and 
maintained in accordance with the instructions. 
Your statutory rights are not affected by this 
warranty.

It is important to register as soon as possible 
online at: smithsep.co.uk/product-registration/.  
This will ensure you will receive prompt and 
efficient service if your product requires attention 
within the warranty period. If you do not register 
your product, you will be required to produce 
proof of purchase prior to receiving service.

For more details please visit our website: 
SmithsEP.co.uk

Disposal

As part of the policy of continuous product 
improvement, Smith’s Environmental Products LTD 
reserves the right to alter specification without 
prior notice.

Products with this symbol (crossed out wheelie 
bin) cannot be disposed as household waste. 
Old electrical and electronic equipment must be 
recycled at a facility capable of handling these 
products and their waste by-products. If you are 
purchasing replacement equipment your retailer 
may offer a ‘take back’ scheme, or will be able to 
give details of the nearest approved authorised 
treatment facility. Proper recycling and waste 
disposal will help conserve resources whilst  
preventing detrimental effects on our health  
and the environment.

WEEE Registered Code: WEE/ED0093VW

 

After sales and spares

If you experience any problems with the use of 
your product, please contact our after-sales office 
+44 (0) 1245 324560. 

For product information, customer services or 
sales support call us on +44 (0) 1245 324900

For the Republic of Ireland, contact MT Agencies 
on 01 864 3363

Sales: [email protected] 
General information: [email protected]

Smith’s Environmental Products Ltd
Blackall Industrial Estate, South Woodham Ferrers, 
Chelmsford, Essex CM3 5UW

SmithsEP.co.uk

@SmithsEP_UK

#ThinkSmiths

Approved CQS ISO 

9001:2015

Certificate No. EM2001002

ISO 14001 

ISO 14001

Summary of Contents for Caspian EC 120

Page 1: ...01 April 2020 SmithsEP co uk 1 Issue 001 April 2020 ENGLISH UK IRL SmithsEP co uk Caspian EC variants with Smart Controls Installation commissioning and user manual 60 90 120 150 180 EC Series Fan Con...

Page 2: ...earthed To avoid the possibility of vibration these units must be fitted to a flat even surface Please note that the guarantee may be invalidated if this product is not installed and used in accordanc...

Page 3: ...is made on behalf of Smith s Environmental Products Limited Salus controller The Salus controller independently complies with the essential requirements and other relevant provisions of Directives 201...

Page 4: ...e or if it is malfunctioning or it is dropped or damaged in any manner Inspect the appliance in accordance with manufacturers instructions The appliance should not be electrically supplied if there is...

Page 5: ...y protected by a Residual Current Device RCD or Ground Fault Circuit Interrupter with a rated residual operating current not exceeding 30mA 10 Prior to any modification being made to the equipment it...

Page 6: ...0 270 A Electrical supply in this side Model A 60 595 90 895 120 1195 150 1495 180 1795 Pipe centres Caspian UV Caspian SL 110 66 45 235 660 135 A Electrical supply in this side Model A 60 595 90 895...

Page 7: ...Issue 001 April 2020 SmithsEP co uk 7 110 65 45 235 1800 270 A Electrical supply in this side Model A 60 595 90 895 120 1195 150 1495 180 1795 Pipe centres Caspian EXT...

Page 8: ...8 SmithsEP co uk Issue 001 April 2020 Control mounting options configurations Predetermined at time of order Internally mounted tamper proof Wall mounted remote Flush mounted...

Page 9: ...ALVE GREEN GREEN GREEN GREEN GREEN BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE RED RED RED RED GREY GREY GREY WHITE WHITE WHITE BROWN BROWN BROWN BROWN BROWN BLUE BLUE B...

Page 10: ...7 0 21 0 Model Heat Output at 65 Heat Output at 60 Heat Output at 55 Heat Output at 50 Low kW Med kW High kW Low kW Med kW High kW Low kW Med kW High kW Low kW Med kW High kW CASPIAN 60 2 3 3 2 4 2 2...

Page 11: ...g based on BS EN442 using mean water temperature 18 C entering air temperature 10 temperature drop Mean water temperature C EAT C 80 to 40 15 1 10 21 0 93 Correction factors Temperature drop C 20 15 1...

Page 12: ...cation Flush mounted and Internal mounted control options are suitable for floor standing and other low applications Wall mounted remote control option should be used for wall and ceiling mounted appl...

Page 13: ...Issue 001 April 2020 SmithsEP co uk 13 Notes...

Page 14: ...sed Pipework must only enter in intended cut outs or knockouts on the header connection side of the heater Note 15mm pipework suitable for heating outputs up to 12kW 22mm should be used where output e...

Page 15: ...OFF F3 F2 F1 V2 V1 N L SALUS FC600 S2 COM S1 UP 60 Fig 4 Fig 1 Fig 2 Fig 3 Fig 5 Fig 6 3 Amp fused spur Supply L N 5 Electrical supply and electrical connection Electrical supply to the unit must be n...

Page 16: ...mostat will remain internally to the unit See wiring diagram S2 and C connections Master slave wiring hard wire A number of units may be controlled from one thermostat For connection details please se...

Page 17: ...connection offline mode Go to https salus controls com uk product fc600 downloads for the full PDF version of the manual Quick user guide for Wi Fi Thermostat Key Function Increase Button Decrease But...

Page 18: ...nsor indicators 23 Sensor indicators 24 Room setpoint temperature 25 Setpoint temperature indicator Schedule Mode Temporary Override Permanent Override LCD Icon descriptions Getting started All units...

Page 19: ...p arrow followed by the tick confirm button See image 1 and 2 M M M M 8 6 5 7 M M 3 4 4 5 Select the thermostat mode although this unit is heating only by setting heating and cooling allows the use of...

Page 20: ...n the App 7 8 Note To view detail of set up operation and parameters please consult the full manual at https salus controls com uk product fc600 downloads Temporary override M 2 Note The temporary ove...

Page 21: ...ll your settings Factory reset will only take effect on the thermostat you are working on 2 4 6 8 M M M M 1 2Sec 2Sec 2Sec 5 7 3 User Guide For further information and to view detail of set up operati...

Page 22: ...culty please contact us on 44 0 1245 324560 It will be helpful if you do not disconnect the heater from the central heating system Maintenance Warning Isolate from the electrical supply before perform...

Page 23: ...register your product you will be required to produce proof of purchase prior to receiving service For more details please visit our website SmithsEP co uk Disposal As part of the policy of continuou...

Page 24: ...ists All products are available nationally from Builders Merchants Plumbers Merchants Heating Equipment Distributors and Kitchen Equipment Distributors In the event of difficulty please contact us or...

Reviews: