Power Button 

-

 Press the power button to turn on the SSRS Display. The system defaults to manual mode

each time it is powered up.

With the SSRS Display turned OFF, the sprayer will  only operate as a conventional rate controller. The
Nozzle Solenoids work as an electric On/Off drip check and work with the boom section On/Off switches.

NOTE: Spraying in the OFF mode will require selecting different tips.

Menu Button 

-

 The menu button is used to enter and exit the menu list. Press menu button to enter the menu

list pages, use the increase/decrease buttons to navigate the menu list highlighting the desired field.Press
the enter button to exit menu structure, highlight the exit menu line and press the menu button.

OPERATION

Auto/Manual Button 

-

 Manual mode is the default mode at power up. Manual mode will pulse nozzle

valves at the duty cycle percentage selected by the increase/decrease buttons. The Manual mode is used
in the event that the SSRS Display fails to automatically control pressure. It is not necessary to change
tips.

Manual Mode can also be used to close all nozzle valves. By toggling down to 10% duty cycle, then
pressing decrease once more. This will close all solenoids and the diagnostic readout will show “OFF”.

NOTE: In the Manual mode the increase/decrease  buttons act like an electronic rotary nozzle  body

with an “infinite” number of tips that can be selected by the operator.

Summary of Contents for Spray Star 2005

Page 1: ...ay Star 2005 2006 2005D 2006D SharpShooter Rate Sync w Envizo Pro II with 18 and 20 Booms July 2016 Operator s Product Support Hwy SS Poplar Ave Cameron WI 54822 1 800 891 9435 productsupport smithco...

Page 2: ...g Instructions 14 16 Envizio Pro II Do s and Don ts 16 SharpShooter RateSync Console Features 17 Initial Set Up of Envizio Pro II 18 21 SharpShooter Rate Sync Control 22 23 Spray Operation 24 25 Re Ca...

Page 3: ...ordering parts The serial number plate on the Spray Star 2000 is located on the right middle main frame Refer to engine manual for placement of engine serial number Refer to engine manual for placemen...

Page 4: ...elease Hydraulic Oil Level Choke Open Choke Closed Hand Throttle Hour Meter Hour Meter Fuse Glow Plug Glow Plug Off Glow Plug On RPM Gasoline Diesel Water Temperature Temperature Light Engine Oil Engi...

Page 5: ...MBOLS No Smoking Moving Parts Manual Operation Pinch Point Step Hot Surface Hydraulic Fluid Penetration Lift Arm Tractor Engage Disengage PTO Ground Speed Fast Slow H High L Low F Forward R Reverse N...

Page 6: ...azardous situa tion that if not avoided will result in death or serious injury This signal word is to be limited to the most extreme situations typically for machine components which for functional pu...

Page 7: ...e available from your autho rized distributor This is a list of decals located on the Spray Star 2000 Part number description and location will help in reorder ing a decals A 15 463 Decal Spray Pump 1...

Page 8: ...all drives and set park brake before starting the engine 12 Never use your hands to search for oil leaks Hydraulic fluid under pressure can penetrate the skin and cause serious injury 13 This machine...

Page 9: ...Check hoses for weak or worn condition before each use Make certain that all connections are tight and secure 11 Do not operate unit with leaks frayed kinked hoses or tubing Repair or replace immediat...

Page 10: ...riable 0 10 m p h 0 16 kph BATTERY Automotive type 24F 12 volt BCI Group Size 24 Cold Cranking Amps 900 minimum Ground Terminal Polarity Negative Maximum Length 10 25 26 cm Maximum Width 6 88 17 cm Ma...

Page 11: ...12 NHS Multi Trac 18 psi 1 3 bar SPEED Infinitely Variable 0 10 m p h 0 16 kph BATTERY Automotive type 24F 12 volt BCI Group Size 24 Cold CrankingAmps 900 minimum Ground Terminal Polarity Negative Max...

Page 12: ...ILL 4 Fill fuel tank located on the left side with Unleaded 87 Octane gasoline minimum Fuel is flammable caution must be used when storing or handling it Do not fill fuel tank while engine is running...

Page 13: ...11 Introduction PARTS MANUALS AVAILABLE ONLINE AT smithco com NOTES...

Page 14: ...top and off by pushing on the bottom G Buzzer The buzzer sounds if the pump is running dry H Ground Speed Cruise Control This rocker switch initiates cruise control by pushing on the top and turning i...

Page 15: ...ruise R Master Boom Switch located on the left floorboard is used to override the master switch on the computer console of the spray systems By pushing down it will turn on off the booms For the 440 S...

Page 16: ...nds to inspect for leaks 6 Check the hydraulic fluid level The hydraulic fluid tank is located on the left side of the machine The fluid level should be 2 2 5 6 4 cm from the top of the tank when cold...

Page 17: ...the battery When charging or working near battery always shield your eyes and always pro vide proper ventilation Battery cable should be disconnected before using Fast Charge Charge battery at 15 amp...

Page 18: ...7 6 28 8 5 32 4 2 15 9 50 3 4 12 2 46 2 5 32 5 5 20 8 100 6 9 17 5 66 2 3 16 3 6 13 6 25 1 7 9 1 34 4 3 16 5 6 21 2 50 33 4 14 3 54 1 3 16 7 9 29 9 100 6 9 18 7 70 8 You can change orifice disc sizes...

Page 19: ...P To Begin a Job Create a Spray Zone Turn Sharpshooter w RateSync On Press Auto Manual button to Auto PSI is preset Use arrow buttons to increase decrease POWER Home Screen Switch Pro AccuBoom Switche...

Page 20: ...re you can Start a New Job 3 New Job Menu 4 Start a New Job Screen Insure Arrow on Tractor is Forward Touch the Yellow New Job Box Touch Icon to Correct if Needed This will bring up the Keyboard Scree...

Page 21: ...Name the New Field Boundary Map it s best to use the same name as the New Job file Touch the Green Check Circle This will return you to the Job As Applied Screen 10 Creating a Field Boundary Drive to...

Page 22: ...dary Tools on Screen 14 Drive the Outline of the Area You will see the Yellow Line that will be the boundary of the Field Boundary located at your selection point Press the Black Pause Box at any time...

Page 23: ...m INITIALSETUP 16 Press the Green Menu Box then the Green Check Box 17 The Spray No Spray Boundary Line will then be represented in Blue and Areas with Application Previously Applied will be Represent...

Page 24: ...ent tips Menu Button The menu button is used to enter and exit the menu list Press menu button to enter the menu list pages use the increase decrease buttons to navigate the menu list highlighting the...

Page 25: ...SharpShooter with Rate Sync system operation Actual pressure effective tip size and duty cycle are displayed in the Manual mode Actual pressure target pressure and duty cycle appear in the AUTO mode A...

Page 26: ...computer must be on for the master boom control switch to work For the 440 System the Master Switch on the computer must be off for the master boom control switch to work Review the capacity of nozzle...

Page 27: ...hose or spray boom with nozzles removed until empty 3 Remove drain coupling again and rinse tank interior thoroughly 4 Rinse exterior of sprayer thoroughly with clean water 5 Remove bowl from sprayer...

Page 28: ...have to be applied so that they get into the soil below the plant leaves This is called soil appli cation In order to do this they are best applied with a large volume of water They are often then wat...

Page 29: ...es Plunger blockage Plunger stuck Plunger blockage results when larger debris catches between the orifice and plunger seal This is the smallest flow passage within the nozzle valve Stuck plungers resu...

Page 30: ...the plunger for wear or damage Replace plunger if worn or damaged Remove debris from nozzle components by washing components with clean water After extended use the soft plunger seal Item 1 will wear...

Page 31: ...39 3 7 325 6 204 0 626535627 37 59213759 38 3 8 334 4 204 0 610047847 36 60287081 37 3 9 343 2 204 0 594405594 35 66433566 36 4 352 204 0 579545455 34 77272727 35 4 1 360 8 204 0 5654102 33 92461197 3...

Page 32: ...30 Reference...

Page 33: ...gteljes tm nyszint Livello di potenza sonora misurato Izm r tais ska as jaudas l menis I matuotas garso stiprumo lygis Livell tal Qawwa tal oss Iggarantit Moc akustyczna mierzona N vel sonoro medido N...

Page 34: ...n valmistajan valtuutus vakuutuksen laadintaan jolla on hallussaan teknisetasiakirjat joka on valtuutettu laatimaan tekniset asiakirjat ja joka on sijoittautunut yhteis n Signature de la personne habi...

Page 35: ...33 Reference NOTES...

Page 36: ...esel Spray Star 2000 REPLACEMENTBELTS 30 137 Spray Pump V Belt SEALKITS 15 301 Power Steering Orbital Motor 15 301 01 Seal Kit 15 839 Hydraulic Cylinder 14 531 Seal Kit 43 116 Wheel Motors 14 080 Seal...

Page 37: ...you need help locating an Authorized Smithco Distributor or if you have questions regarding your warranty rights or responsibilities you may contact us at Smithco Product Support Department 200 W Pop...

Page 38: ...ty gives you specific legal rights and you may also have other rights which vary from state to state THERE ARE NO OTHER EXPRESS WARRANTIES OTHER THAN THOSE SET FORTH ABOVE ALL IMPLIED WARRANTIES OF ME...

Reviews: