Smith Meter UPT Installation Service Download Page 6

Issue/Rev. 0.7 (11/17)

Page 6

 • 

MN01045

Step 9.

   a.  Tighten T-Bar with the encoder attached

 

          onto housing.

             b.  Tighten terminal block mounting bracket  

          screws.

Step 11.

  a.  Insert shaft down through the top and 

             through the encoder.

Note: 

You may need to tap the shaft until it slides through completely. 

             b.  Insert the cotter pin and tighten both set
            screws.

Note:

 Make sure that the torque arm is approximately 1/8" above

the T-bar base.

Note:

 Ensure that the washer is between the cotter pin and the 

housing. Apply a light coat of Loctite 222 (included) to the set screw

threads prior to tightening. Make certain to not over tighten the set

screws to avoid damage to the set screw heads, and the encoder.

Rotate the output shaft and check to ensure that the input shaft is

rotating as well.

Step 10.

 Add thin coat of grease to shaft prior to  

         re-assembly.

9 8 7 6 5 4 3 2 1

Step 10

Step 11a

9 8 7 6 5 4 3 2 1

Step 11b

9 8 7 6 5 4 3 2 1

Step 9a

Step 9b

9 8 7 6 5 4 3 2 1

1/8"

Summary of Contents for UPT

Page 1: ...nnsylvania 16514 Prior to installation the unit should be stored in its original packing case and protected from adverse weather condi tions and abuse Mechanical Installation When ordered with a Smith...

Page 2: ...ed 10 If desired a seal wire can be installed like a belt around the middle of the UPT Transmitter cover and housing to prevent unauthorized tampering with internals Note With the calibrator removed f...

Page 3: ...nnections Rotation of Transmitter Shaft Reference Dimensions Drawing Below Electronics Ground white 1 Input Power 12 24 Vdc brown 2 Counter Clockwise Clockwise Channel B Output grey 3 Leading Lagging...

Page 4: ...acket from enclosure b Remove screws holding T Bar in place 1 2 3 4 5 6 7 8 9 9 8 7 6 5 4 3 2 1 Step 4a Step 4b Step 3 Remove the coupling and pull the shaft out Step 2 a Remove hairspring cotter pin...

Page 5: ...minal block Step 7 Inspect terminal block and encoder for damage corrosion or wear and replace if needed Step 6 Step 8 a Re insert o ring tighten cover over o ring and then tighten aluminum piece with...

Page 6: ...m is approximately 1 8 above the T bar base Note Ensure that the washer is between the cotter pin and the housing Apply a light coat of Loctite 222 included to the set screw threads prior to tightenin...

Page 7: ...l corrosion protection to the flame path TechnipFMC synthetic grease P N 644886401 is recommended Apply a nickel based anti size lubricant to all cover fasteners TechnipFMC P N 646002401 is recommende...

Page 8: ...moisture can enter into the UPT housing TechnipFMC com TechnipFMC 2017 MN01045 Issue Rev 0 7 11 17 TechnipFMC FMC Technologies Measurement Solutions Inc 500 North Sam Houston Parkway West Suite 100 Ho...