BOX
S
220
innovative in electronics
INSTRUCTION MANUAL
DESCRIPTION
BASE STATION CONTROLLER
SMINN's base station controllers are developed
with state-of-the-art electronic devices. They
provide a high degree of operating reliability and
security. Equipped with a solid communication
bus RS 485 that allows more mounting versatility
and makes them more immune to interference.
They are designed to provide the activation and
movement order to SMINN motor controllers,
alarms, access control and home automation
systems, etc. They are suitable for industrial,
commercial and/or residential environments.
These devices are built using high quality
materials and components and the latest
technology. They are devices that observe the
current regulations for usage in residential,
commercial and light industry environments.
OPERATION
When a code from a SMINN key-tag or keypad is received, the base
station controller checks if it is already registered in the memory. If it is
registered and not blocked, the relay will activate.
ERASE MEMORY
The memory can only be erased using SMINN's programming console
and knowing its PIN, avoiding accidental or malicious erasures.
BLOCKING A CODE IN THE MEMORY
A transmitter code cannot be simply erased from the memory, but it can
be blocked so it won't work anymore. Blocking codes in the memory can
only be done using a SMINN programming console and knowing its PIN.
MANUAL PROGRAMMING
The steps to program the receiver are detailed below.
1. Press and hold the K1 button (fig. 1).
2. Approach to the reader the key-tag you want to record. When the
reader sends the code, the receiver memorizes it and it will beep twice as
a validation signal.
3. Repeat this process for as many key codes you want to register in
memory.
4. Release the programming button of the receiver.
Pressing any other channel will not make any effect.
BACKUP COPY
Although the device is protected against power line disturbances and
electrical surges, it is important to keep a backup of the memory card in
case of breakdown or damages caused by external circumstances such
as electric storms, theft, improper handling, etc.
INSTALLATION
SMINN's base station controller is ready to be easily fixed on a wall using
the supplied wall plugs and screws. Before connecting or operating the
device the power supply switch or differential shall be disconnected.
Specialized and/or skilled personnel will do the installation, using
properly protected cable of enough gauge. Take into account that
devices permanently connected to the mains need to have an accessible
connection device (i.e. a magnetothermic switch). The wiring should be
done following the instructions printed in the serigraphy of the circuit
board. Make sure that the memory is inserted and properly configured.
After programming and verifying the equipment, close the case with the
supplied top.
SMINN'S BASE STATION MOTOR CONTROLLERS INCLUDE A LIGHT
SIGNAL TO KNOW IF THE EQUIPMENT IS POWERED.
CONNECTION
Wiring is easy using the terminal block for three circuits. Readers are
connected using just 4 wires on the terminals 3 to 6. 2 of them are for
power and the other two for the RS485 data bus.
Terminal
Function
Note
1
2
3
Positive (+)
4
Negative (-)
5
Line (A)
6
Line (B)
7
8
Activation relay
9
The RS485 BUS is used in Half / Duplex mode with two wires: A and B.
All elements of the BUS must have the same connection. A wires
connected to A, and B to B (they must not be exchanged).
Power
Power input at 230 V or 12/24 AC / DC
(depending on model)
Power output to readers/keypads
Apply to the BUS RS485 line
(1)
12/24 V AC/DC
ti
depending
op onal
mod
230 VAC
(1)
N
RUN
K1
OK
RD
125
RD
125
KB
120
Activation signal to the control panel
FUS. 0.3A
3
+
A B
NA
C
NC
-
4
5
6
7
8
9
+
A
B
-
L
Rev
. 16
14