5 Installation
5.1 Minimum clearance to combustible surfaces
Freestanding cooker
A
600 mm (Overhead) measured from the
highest part of the highest burner and 750
mm for an exhaust fan.
B
200 mm (Vertical combustible surface)
measured form the edge of the nearest
burner.
C
10 mm (Horizontal combustible surface)
below the hob.
5.2 Gas connection
General informations
This appliance is suitable for installation with
Natural Gas or ULPG (propane/butane).
Refer to “” paragraph for the relevant
burner pressure and appropriate injector
sizes. When the appliance is to be
connected to Natural Gas then the
pressure regulator supplied must be fitted to
the gas inlet. A test point (for checking the
gas pressure) is supplied either with the
regulator or as a separate fitting in the case
of ULPG (propane) appliances.
Refer to AS/NZS 5601
(Protection of a combustible
surface) if the above minimum
clearances cannot be achieved.
The appliance connection point
shall be accessible with the
appliance installed.
Maximum height of the top pan
support with respect to the surface
that supports the appliance is
912mm.
Gas leak
Danger of explosion
• After carrying out any operation, check
that the tightening torque of gas
connections is between 10 Nm and 15
Nm.
• If required, use a pressure regulator that
complies with current regulations.
• At the end of the installation, check for
any leaks with a soapy solution, never
with a flame.
• Installation with flexible hose must be
carried out so that the length of the
piping does not exceed 1,2 metres
when fully extended; make sure that the
hoses do not come into contact with
moving parts and that they are not
crushed in any way.
• The hoses should not come into contact
with moving parts and should not be