Instructions
62
• Installation using a hose must be
carried out so that the length of the
hose does not exceed 2 metres
when fully extended for steel hoses
and 1.5 metres for rubber hoses.
• The hoses should not come into
contact with moving parts and
should not be crushed in any way.
• If required, use a pressure
regulator that complies with
current regulations.
• After carrying out any operation,
check that the tightening torque of
gas connections is between
10 Nm and 15 Nm.
• At the end of the installation, check
for any leaks with a soapy
solution, never with a flame.
• Have the electrical connection
performed by authorised
technicians.
• The appliance must be connected
to ground in compliance with
electrical system safety standards.
• Use cables withstanding a
temperature of at least 90 °C.
• The tightening torque of the screws
of the terminal board leads must
be 1.5 - 2 Nm.
For this appliance
• Ensure that the appliance is
switched off before replacing the
bulb.
• Do not rest any weight or sit on the
open door of the appliance.
• Take care that no objects are stuck
in the doors.
1.2 Manufacturer liability
The manufacturer declines all liability
for damage to persons or property
caused by:
• Use of the appliance other than
that specified;
• failure to comply with the
instructions in the user manual;
• tampering with any part of the
appliance;
• use of non-original spare parts.