![Smeg SY93-1 Manual Download Page 26](http://html1.mh-extra.com/html/smeg/sy93-1/sy93-1_manual_1302770026.webp)
60 - INSTALLATION
914779640/A
It is possible to identify the available gas types based on the country the appliance is to be installed
in. Refer to the heading number to identify the correct values in the “Burner and nozzle characteristics
tables".
Burner and nozzle characteristics tables
5 Natural Gas G25
G25
20 mbar
•
6 Natural Gas G2.350
G2.350
13 mbar
•
7 LPG G30/31
G30/31
28-30/37 mbar
•
•
•
•
•
•
G30/31
30/30 mbar
•
•
•
•
8 LPG G30/31
G30/31
37 mbar
•
9 LPG G30/31
G30/31
50 mbar
•
•
10 Town Gas G110
G110
8 mbar
•
•
1 Natural Gas G20 - 20 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
72
97
115
145
Pre-chamber (printed on nozzle)
(X)
(Z)
(Y)
(F3)
Reduced flow rate (W)
400
500
800
1200
2 Natural Gas G20 - 25 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.1
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
72
94
110
145
Pre-chamber (printed on nozzle)
(X)
(Z)
(H8)
(H3)
Reduced flow rate (W)
400
500
800
1200
3 Natural Gas G25.3 - 25 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
72
94
121
143
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F2)
(F2)
Reduced flow rate (W)
400
500
800
1200
4 Natural Gas G25.1 - 25 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.1
1.8
3.0
4.1
Nozzle diameter (1/100 mm)
77
100
134
152
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1200
5 Natural Gas G25 - 20 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
3.9
Nozzle diameter (1/100 mm)
77
100
134
165
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(H3)
Reduced flow rate (W)
400
500
800
1200
6 Natural Gas G2.350 - 13 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.75
2.9
3.7
Nozzle diameter (1/100 mm)
94
120
165
190
Pre-chamber (printed on nozzle)
(Y)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1200
Gas types
IT
GB
IE
FR
BE
DE
AT
NL
ES
PT
RU
SE
DK
FI
NO
PL
HU